Evaluating Performance Limitations of Movable Partition Systems to Achieve Spatial Flexibility in Convention Centres in Uyo

Authors

OBASI-IKEKWE, Deborah Uchechi

Department of Architecture, Rivers State University, Port Harcourt (Nigeria)

OKEY-EJIOWHOR, Caleb

Department of Architecture, Rivers State University, Port Harcourt (Nigeria)

ESAU, James Esau

Department of Architecture, Rivers State University, Port Harcourt (Nigeria)

Article Information

DOI: 10.51584/IJRIAS.2026.11060262

Subject Category: Architecture

Volume/Issue: 11/6 | Page No: 3466-3477

Publication Timeline

Submitted: 2026-06-28

Accepted: 2026-07-03

Published: 2026-07-15

Abstract

The growing demand for multifunctional convention centres has increased the need for interior spaces that can be reconfigured efficiently without compromising user comfort or operational performance. Movable partition systems have become an important architectural solution for achieving spatial flexibility by allowing large halls to accommodate multiple events simultaneously. However, their effectiveness is often constrained by acoustic deficiencies, operational inefficiencies, maintenance challenges, and inadequate integration within the building. This study evaluates the performance limitations of movable partition systems in achieving spatial flexibility in convention centres, with reference to Uyo, Akwa Ibom State, Nigeria. It is pursued through two objectives: identifying the types of partition system, acoustic, operational, and material constraints that limit performance; and proposing architectural improvements for convention centres in Uyo. A mixed-method research approach was adopted, combining a systematic review of existing literature, comparative case studies of ExCeL London and Convene 155 Bishopsgate, a structured field survey of three convention facilities in Uyo, and semi-structured interviews with facility managers and architectural practitioners. Field evidence from the Akwa Ibom Tropicana Resort, Ibom Hotel and Golf Resort Facilities, and Emerald Event Center confirms that acoustic performance remains the most critical determinant of partition effectiveness, with sound leakage through joints, seals, and adjacent building elements identified by both the literature and local stakeholders as the primary cause of spatial functionality failure. Operational factors including inadequate storage, mechanical wear, inefficient circulation planning, and inappropriate material selection also significantly influence long-term performance and adaptability. Based on the evidence from literature, case studies, and local field data, the study proposes a Performance-Based Movable Partition Design Framework (PMPDF) integrating acoustic performance, operational efficiency, material and structural integration, and space planning as interconnected design considerations. The study concludes that movable partition systems should be treated as integral components from the conceptual stage rather than secondary building elements.

Keywords

movable partition, convention centre, spatial flexibility, acoustic performance

Downloads

References

1. Adewale, B. A., & Ewuoso, E. A. (2023). Assessment of daylighting strategies in convention centres: A review from 1990 to 2023. Journal of Environment Sciences (JOES), 22(1). ISSN 1118-8936. [Google Scholar] [Crossref]

2. Akwa Ibom State Government. (2025). We're preparing A'Ibom for growth beyond oil — Gov Umo Eno. Official Press Release. https://akwaibomstate.gov.ng [Google Scholar] [Crossref]

3. Andrea, S., John, L. D., & Paolo, B. (2020). A review of the different approaches to predict sound transmission loss of building partitions. Sage Journals, 27(3), 253–279. https://doi.org/10.1177/1351010X20911599 [Google Scholar] [Crossref]

4. Bob G., et al. (2019). Reversible and adaptable building materials and components. Buildings, 9(3). https://doi.org/10.3390/buildings9030070 [Google Scholar] [Crossref]

5. Borzym, J. (2021). Acoustical performance of horizontal-sliding-panel operable partition walls. INTER-NOISE and NOISE-CON Congress and Conference Proceedings, 263(1), 5125–5130. https://doi.org/10.3397/IN-2021-2974 [Google Scholar] [Crossref]

6. Braun, V., & Clarke, V. (2006). Using thematic analysis in psychology. Qualitative Research in Psychology, 3(2), 77–101. https://doi.org/10.1191/1478088706qp063oa [Google Scholar] [Crossref]

7. Creswell, J. W., & Plano Clark, V. L. (2018). Designing and conducting mixed methods research (3rd ed.). SAGE Publications. https://www.scirp.org/reference/referencespapers?referenceid=2697821 [Google Scholar] [Crossref]

8. David, E., & Fergus, F. (2011). The identification of flanking paths in buildings. Architectural Science Review, 25(4), 106–111. https://doi.org/10.1080/00038628.1982.9696507 [Google Scholar] [Crossref]

9. Denzin, N. K. (1978). The research act: A theoretical introduction to sociological methods (2nd ed.). McGraw-Hill. [Google Scholar] [Crossref]

10. Eze, M. I., Agbonome, P., Barnaby, J., Agu, A., Igwegbe, U., & Nwanegbo, G. T. (2023). Space efficiency and circulation: Parameters for a functional convention centre in international markets. International Journal of Innovative Environmental Studies Research, 11(3), 23–27. [Google Scholar] [Crossref]

11. Geldermans, B., Tenpierik, M., & Luscuere, P. (2019). Circular and flexible indoor partitioning: A design conceptualization of innovative materials and value chains. Buildings, 9(9), Article 194. https://doi.org/10.3390/buildings9090194 [Google Scholar] [Crossref]

12. Huang, J. (2011). Design and selection of movable partition systems for multifunctional venues. Building Science Review, 14(2), 45–58. [Google Scholar] [Crossref]

13. ITB Nigeria Limited. (2020). Akwa-Ibom International Convention Centre. https://www.itbng.com/akwa-ibom-international-convention-centre/ [Google Scholar] [Crossref]

14. Jurdy, B., & Gray, K. (2016). A case for modular partitions in healthcare facilities. The Journal of the Acoustical Society of America, 140(4), 3237. https://doi.org/10.1121/1.4970236 [Google Scholar] [Crossref]

15. Luster, A. (2017). Analysis of lighting schemes in public assembly rooms for improved energy performance [Master's thesis]. University of Arizona. https://repository.arizona.edu/handle/10150/624134 [Google Scholar] [Crossref]

16. Punch Newspapers. (2026, May 7). A'Ibom gov hails progress at convention arena, hotel project. https://punchng.com [Google Scholar] [Crossref]

17. Schmidt III, W., Campioli, A., & Lavagna, M. (2010). Flexibility and adaptability in design: Towards a definition and evaluation method. Open House International, 35(4), 76–84. [Google Scholar] [Crossref]

18. Sentagi, S. U., Randy, F. F., Joko, S., & Kristina, W. (2019). Study of partition walls to minimise leaking sound in counselling rooms. AIP Publishing, 2088(1). https://doi.org/10.1063/1.5095342 [Google Scholar] [Crossref]

19. Wu, A., & Weber, K. (2005). Convention centre facilities, attributes and services: The delegates' perspective. Asia Pacific Journal of Tourism Research, 10(4), 399–410. https://doi.org/10.1080/10941660500363736 [Google Scholar] [Crossref]

20. Yeh, B., Huang, C.-H., Chou, C.-W., & Lai, R.-P. (2011). Sound insulation performance of joints spots: A case study of movable partition. Conference paper. https://www.researchgate.net/publication/290280875 [Google Scholar] [Crossref]