Parametric Electromagnetic Modeling, Hardware Realization, and Experimental Performance Characterization of a Direct-Drive Rim-Integrated Permanent Magnet
Authors
Department of Physics and Electronics, Adekunle Ajasin University, Akungba-Akoko, Ondo State (Nigeria)
Department of Physics and Electronics, Adekunle Ajasin University, Akungba-Akoko, Ondo State (Nigeria)
Department of Physics and Electronics, Adekunle Ajasin University, Akungba-Akoko, Ondo State (Nigeria)
Department of Physics and Electronics, Adekunle Ajasin University, Akungba-Akoko, Ondo State (Nigeria)
Department of Physics and Electronics, Adekunle Ajasin University, Akungba-Akoko, Ondo State (Nigeria)
Article Information
Publication Timeline
Submitted: 2026-11-06
Accepted: 2026-11-11
Published: 2026-11-24
Abstract
This study presents the electromagnetic modeling, hardware realization, and empirical performance characterization of a direct-drive, rim-integrated permanent magnet synchronous generator (PMSG) designed for stationary bicycle biomechanical energy harvesting. To eliminate mechanical drivetrain friction, 40 sintered Neodymium-Iron-Boron (NdFeB, Grade N42, Br =1.414T) permanent magnets were mounted in an alternating radial polarity sequence (N–S–N–S) along the perimeter of a 700c bicycle wheel rim, forming a 40-pole (p = 20 pole pairs) rotor. The rotor interacts across a 4.0mm nominal air gap with four series-connected stationary copper stator coils (AWG 26, 85 turns per coil, Nt = 340 total turns). To harvest energy effectively across variable human pedaling cadences, the generated low-frequency alternating current (AC) is conditioned via a capacitive voltage doubler, a full-wave bridge rectifier, and an LM7805 linear regulator (5.0V USB output) coupled to a 12 V, 7 Ah sealed lead-acid (SLA) battery. A PIC16F877A microcontroller-based data acquisition subsystem continuously logged wheel speed, terminal voltage, and signed charging current to an SD card at 5-second intervals. Experimental trials across 20 human operators over 5-minute intervals (100 minutes cumulative runtime) demonstrated that rotational speeds exceeding 150 RPM surpass the 12.6V battery charging threshold, delivering net positive charge (∆Q = 0.0850 Ah to 0.1267 Ah per trial). The prototype achieved a peak rotational speed of 298.35RPM, a peak charging current of 2.15A, and a maximum electrical power output of 25.92W (Operator 19), with an overall electromechanical-to-storage system efficiency of 47.61 %. Analytical flux-linkage modeling yielded a DC voltage constant of Kgen,DC = 0.0641V/RPM, aligning closely with empirical open-circuit measurements. Open-circuit relaxation tests confirmed true electrochemical state-of-charge (SoC) gains of + 0.006 V to + 0.011 V (≈ 0.5 % – 0.9 % SoC) per 5-minute session. Constructed at a total cost of ₦96,940 (≈ 62 USD), the system demonstrates a viable, low-maintenance solution for off-grid auxiliary power generation and fitness telemetry.
Keywords
Biomechanical energy harvesting; Direct-drive generator; Permanent magnet synchronous generator (PMSG); Neodymium magnet; Embedded data acquisition; Off-grid energy storage
Downloads
References
1. Adewole, A. O., & Kiptoo, M. (2020). Energy poverty and decentralized renewable power generation in sub-Saharan Africa: A review of rural and peri-urban energy access models. Journal of Cleaner Production, 268, 122134. https://doi.org/10.1016/j.jclepro.2020.122134 [Google Scholar] [Crossref]
2. Akinyele, D., Belikov, J., & Levron, Y. (2018). Battery storage technologies for electrical applications: Impact in stand-alone photovoltaic systems. Energies, 11(10), 2734. [Google Scholar] [Crossref]
3. https://doi.org/10.3390/en11102734 [Google Scholar] [Crossref]
4. Baker, N. J., & Spooner, E. (2002). Direct-drive permanent-magnet generators for small-scale renewable energy systems. IEE Proceedings - Electric Power Applications, 149(4), 249–256. [Google Scholar] [Crossref]
5. https://doi.org/10.1049/ip-epa:20020489 [Google Scholar] [Crossref]
6. Beretta, M., & Caputo, A. C. (2022). Design and experimental testing of a human-powered pedal generator for off-grid emergency charging applications. Energy Reports, 8, 4112–4124. [Google Scholar] [Crossref]
7. https://doi.org/10.1016/j.egyr.2022.03.045 [Google Scholar] [Crossref]
8. Bhattacharyya, S. C. (2012). Energy access problem of the poor: Opportunities and challenges for micro-grids in developing countries. Energy Policy, 42, 494–502. [Google Scholar] [Crossref]
9. https://doi.org/10.1016/j.enpol.2011.12.014 [Google Scholar] [Crossref]
10. Bhattacharyya, S. C., & Palit, D. (2016). Mini-grid based off-grid electrification to enhance electricity access in developing countries: What policies may be required? Energy Policy, 94, 166–178. [Google Scholar] [Crossref]
11. https://doi.org/10.1016/j.enpol.2016.04.010 [Google Scholar] [Crossref]
12. Chapman, S. J. (2012). Electric machinery fundamentals (5th ed.). McGraw-Hill Education. [Google Scholar] [Crossref]
13. Chen, Y., Pillay, P., & Khan, A. (2005). PM wind generator topologies. IEEE Transactions on Industry Applications, 41(6), 1619–1626. https://doi.org/10.1109/TIA.2005.858261 [Google Scholar] [Crossref]
14. Chowdhury, S. A., & Razzak, M. A. (2019). Design and simulation of a low-speed hub alternator for stationary bicycle power generation. IEEE Transactions on Energy Conversion, 34(2), 890–898. https://doi.org/10.1109/TEC.2018.2882201 [Google Scholar] [Crossref]
15. Deng, W., & Wang, Y. (2021). Recent advances in biomechanical energy harvesting: Mechanisms, materials, and applications. Nano Energy, 84, 105889. https://doi.org/10.1016/j.nanoen.2021.105889 [Google Scholar] [Crossref]
16. El-Refaie, A. M. (2010). Fractional-slot concentrated-windings synchronous permanent magnet machines: Opportunities and challenges. IEEE Transactions on Industrial Electronics, 57(1), 107–121. https://doi.org/10.1109/TIE.2009.2030211 [Google Scholar] [Crossref]
17. Gieras, J. F. (2010). Permanent magnet electric machines: Design and applications (2nd ed.). CRC Press. [Google Scholar] [Crossref]
18. Hanselman, D. C. (2006). Brushless permanent magnet motor design (2nd ed.). Magna Physics Publishing. [Google Scholar] [Crossref]
19. Hayt, W. H., Buck, J. A., & Akhtar, M. J. (2014). Engineering electromagnetics (8th ed.). McGraw-Hill Education. [Google Scholar] [Crossref]
20. Jansen, A. J., & Stevels, A. L. N. (2006). Combining eco-design and user benefits from human-powered energy systems, a win-win situation. Journal of Cleaner Production, 14(15–16), 1299–1306. https://doi.org/10.1016/j.jclepro.2005.11.023 [Google Scholar] [Crossref]
21. Khaligh, A., & Onar, O. C. (2017). Energy harvesting: Solar, wind, and energy harvesting modules. CRC Press. [Google Scholar] [Crossref]
22. Kuang, Y., & Zhu, M. (2017). Characterisation of a knee-joint energy harvester powering a wireless communication sensing node. Smart Materials and Structures, 25(5), 055013. [Google Scholar] [Crossref]
23. https://doi.org/10.1088/0964-1726/25/5/055013 [Google Scholar] [Crossref]
24. Kwan, T. H., & Wu, X. (2016). Efficiency analysis and optimization of friction-driven vs. direct-drive biomechanical energy harvesters. Applied Energy, 179, 1188–1198. [Google Scholar] [Crossref]
25. https://doi.org/10.1016/j.apenergy.2016.07.086 [Google Scholar] [Crossref]
26. Li, Z., & Chen, G. (2019). Design optimization of direct-drive permanent magnet synchronous generators for low-speed energy harvesting applications. IET Electric Power Applications, 13(7), 985–993. https://doi.org/10.1049/iet-epa.2018.5712 [Google Scholar] [Crossref]
27. Lipo, T. A. (2017). Introduction to AC machine design. John Wiley & Sons. [Google Scholar] [Crossref]
28. Mazidi, M. A., McKinlay, R. D., & Causey, D. (2008). PIC microcontroller and embedded systems: Using Assembly and C for PIC18. Pearson Prentice Hall. [Google Scholar] [Crossref]
29. Mitcheson, P. D., Yeatman, E. M., Rao, G. K., Holmes, A. S., & Yeatman, T. (2008). Energy harvesting from human and machine motion for wireless electronic devices. Proceedings of the IEEE, 96(9), 1457–1486. https://doi.org/10.1109/JPROC.2008.927494 [Google Scholar] [Crossref]
30. Mukherjee, S., & Mandal, N. (2020). Voltage multiplier-based low-voltage AC-DC power conditioning topologies for electromagnetic energy harvesters. IEEE Transactions on Circuits and Systems II: Express Briefs, 67(11), 2612–2616. https://doi.org/10.1109/TCSII.2020.2967412 [Google Scholar] [Crossref]
31. Niu, S., Ho, S. L., & Fu, W. N. (2014). Performance analysis of a novel direct-drive permanent-magnet generator for human power harvesting. IEEE Transactions on Magnetics, 50(11), 1–4. [Google Scholar] [Crossref]
32. https://doi.org/10.1109/TMAG.2014.2323214 [Google Scholar] [Crossref]
33. Olabi, A. G., Wilberforce, T., Sayed, E. T., Elsaid, K., & Abdelkareem, M. A. (2021). Prospects of fuel cell and human-powered hybrid energy systems for off-grid applications. Energy, 226, 120351. [Google Scholar] [Crossref]
34. https://doi.org/10.1016/j.energy.2021.120351 [Google Scholar] [Crossref]
35. Parasuraman, S., & Elumalai, V. (2021). Performance characteristics of coreless permanent magnet axial flux generators for localized energy harvesting. Journal of Electrical Engineering & Technology, 16(4), 1985–1996. https://doi.org/10.1007/s42835-021-00720-z [Google Scholar] [Crossref]
36. Piller, S., Perrin, M., & Jossen, A. (2001). Methods for state-of-charge determination and their applications. Journal of Power Sources, 96(1), 113–120. https://doi.org/10.1016/S0378-7753(01)00560-2 [Google Scholar] [Crossref]
37. Polinder, H., van der Pijl, F. F., de Vries, G. J., & Heck, M. B. (2006). Comparison of direct-drive and geared generator concepts for wind turbines. IEEE Transactions on Energy Conversion, 21(3), 725–733. https://doi.org/10.1109/TEC.2006.875476 [Google Scholar] [Crossref]
38. Pyrhönen, J., Jokinen, T., & Hrabovcová, V. (2013). Design of rotating electrical machines (2nd ed.). John Wiley & Sons. [Google Scholar] [Crossref]
39. Rizzoli, G., Mengoni, M., Zarri, L., & Tani, A. (2022). Electromagnetic design and parasitic loss minimization in rim-mounted permanent magnet generators. IEEE Access, 10, 43102–43114. [Google Scholar] [Crossref]
40. https://doi.org/10.1109/ACCESS.2022.3168901 [Google Scholar] [Crossref]
41. Rubeis, T. D., Nardi, I., & Ambrosini, D. (2019). Off-grid human-powered systems: Empirical evaluation of pedal-generator power conversion efficiencies. Energy Conversion and Management, 196, 1245–1256. https://doi.org/10.1016/j.enconman.2019.06.071 [Google Scholar] [Crossref]
42. Sadiku, M. N. O. (2018). Elements of electromagnetics (7th ed.). Oxford University Press. [Google Scholar] [Crossref]
43. Sahoo, S., & Dash, S. S. (2023). Design and performance evaluation of a multi-pole permanent magnet generator for low-RPM renewable and human-powered applications. Electrical Engineering, 105(3), 1543–1556. https://doi.org/10.1007/s00202-023-01748-1 [Google Scholar] [Crossref]
44. Spooner, E., & Williamson, A. C. (1996). Direct-coupled, permanent-magnet generators for wind turbines. IEE Proceedings - Electric Power Applications, 143(1), 1–8. https://doi.org/10.1049/ip-epa:19960001 [Google Scholar] [Crossref]
45. Starner, T. (1996). Human-powered computing. IBM Systems Journal, 35(3–4), 618–629. [Google Scholar] [Crossref]
46. https://doi.org/10.1147/sj.353.0618 [Google Scholar] [Crossref]
47. Tiwari, R., & Patel, V. (2018). Comparative performance analysis of mechanical drivetrain efficiency in bicycle power generation systems. Renewable Energy Focus, 26, 45–53. [Google Scholar] [Crossref]
48. https://doi.org/10.1016/j.ref.2018.07.003 [Google Scholar] [Crossref]
49. Valik, L., & Konecny, P. (2020). Embedded microcontroller-based real-time telemetry systems for decentralized renewable micro-generators. Sensors, 20(14), 3921. https://doi.org/10.3390/s20143921 [Google Scholar] [Crossref]
50. Wang, C., & Zhang, J. (2015). Direct-drive biomechanical energy harvesting using high-grade NdFeB permanent magnet configurations. Applied Physics Letters, 107(12), 123902. [Google Scholar] [Crossref]
51. https://doi.org/10.1063/1.4931702 [Google Scholar] [Crossref]
52. Wang, J., & Howe, D. (2005). Design and optimization of permanent-magnet machines for direct-drive applications. IEEE Transactions on Magnetics, 41(10), 3922–3924. [Google Scholar] [Crossref]
53. https://doi.org/10.1109/TMAG.2005.854964 [Google Scholar] [Crossref]
54. Wong, K. C., & Chen, Y. S. (2021). Torque ripple reduction and flux enhancement in rim-integrated permanent magnet synchronous generators. IET Electric Power Applications, 15(5), 612–624. [Google Scholar] [Crossref]
55. https://doi.org/10.1049/elp2.12051 [Google Scholar] [Crossref]
56. Xu, D., & Zhu, Z. Q. (2017). Parametric analysis of cogging torque and back-EMF in permanent magnet machines with perimeter magnet arrangements. IEEE Transactions on Magnetics, 53(6), 1–9. [Google Scholar] [Crossref]
57. https://doi.org/10.1109/TMAG.2017.2669112 [Google Scholar] [Crossref]
58. Zhao, X., & Guerrier, P. (2018). Microcontroller-based charge controllers for battery storage in human-powered generator systems. IEEE Transactions on Power Electronics, 33(9), 7780–7791. [Google Scholar] [Crossref]
59. https://doi.org/10.1109/TPEL.2017.2765410 [Google Scholar] [Crossref]
Metrics
Views & Downloads
Similar Articles
- A Comparative Study on the Thermal and Electrical Conductivity of Common Materials
- Thickness Dependent Thermoelectric Properties of Pb0.4In0.6Se Thin Films Deposited by Physical Evaporation Technique
- Optimization of a Patch Antenna Using Genetic Algorithm
- Kinematic Constraints On Brown Dwarf Atmospheric Variability And Evidence For Bimodal Formation From Multi-Survey Analysis
- Reservoir Characterization through the Application of Petrophysical Evaluation of Well Logs of Animaux Field, Niger Delta Basin, Nigeria