Performance Optimization of a Kidney Loop Filtration System for Hydraulic Oil Contamination Control in CAT D6R2 XL Dozers

Authors

Abdul Halim

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Bagas Putra Pratama

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Abdul Muis

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Muh. Taufik

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Abdul Halik

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Misru Razi

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

Munawir

Department of Mechanical Engineering, Politeknik Negeri Samarinda (Indonesia)

La Bima

Department of Electrical Engineering, Politeknik Negeri Samarinda, East Kalimantan, Indonesia (Indonesia)

Article Information

DOI: 10.51584/IJRIAS.2026.11090161

Subject Category: Mechanical Engineering

Volume/Issue: 11/9 | Page No: 2247-2256

Publication Timeline

Submitted: 2026-10-03

Accepted: 2026-10-08

Published: 2026-10-24

Abstract

Particle contamination in hydraulic oil can affect the reliability of hydraulic systems in heavy equipment. This study evaluates a fabricated Kidney Loop system installed and tested on a CAT D6R2 XL Dozer for its ability to reduce particulate contamination in hydraulic oil. An applied experimental approach was used, with oil samples collected before filtration and after 8 and 16 hours of filtration. Samples were analyzed using a Liquid Particle Counter (LPC 500) at the S.O.S Laboratory of PT Trakindo Utama Balikpapan. The reported mean particle count in the ≥14 µm channel decreased from 609.85 particles/mL before filtration to 110.95 particles/mL after 8 hours and 83.55 particles/mL after 16 hours, corresponding to reductions of approximately 81.8% and 86.3%, respectively. The study also reports a single-channel cleanliness parameter for the ≥14 µm channel of 16.30 before filtration, 13.90 after 8 hours, and 13.45 after 16 hours. These values are treated here as reported channel-specific parameters, not as complete three-channel ISO 4406 codes. The measured flow rate was 11.5 LPM at 40–60 psi and 13 LPM at 80–100 psi. Because the comparative test changed both working pressure and filter-element condition, the individual effect of pressure cannot be isolated. The assessment was limited to particulate contamination; water content, kinematic viscosity, and spectrometric wear-metal analysis were not measured. Future testing should independently control pressure and filter-element condition, verify all ISO 4406 channels against the raw laboratory data, and extend fluid diagnostics beyond particle counting.

Keywords

Kidney Loop; hydraulic oil; particle contamination

Downloads

References

1. Abduazizov, N., Toshov, J. B., Abdiyeva, L., Khuangan, N., Zhuraev, A., Baratov, B., & Rabatuly, M. (2026). Assessment of factors contributing to failures in hydraulic systems of mining excavators. Mining of Mineral Deposits, 20(2), 31. https://doi.org/10.33271/mining20.02.031 [Google Scholar] [Crossref]

2. Novak, N., Trajkovski, A., Kalin, M., & Majdič, F. (2023). Degradation of hydraulic system due to wear particles or medium test dust. Applied Sciences, 13(13), 7777. [Google Scholar] [Crossref]

3. https://doi.org/10.3390/app13137777 [Google Scholar] [Crossref]

4. Jannifar, A., Yuniati, Y., & Muslem, M. (2016). Analysis of hydraulic-oil contamination particles in Hitachi excavators used in C-mining operations in North Aceh. Jurnal POLIMESIN, 14(1). [Google Scholar] [Crossref]

5. https://doi.org/10.30811/jpl.v14i1.295 [Google Scholar] [Crossref]

6. Karanović, V., Andrić, S., Jocanović, M., Orošnjak, M., & Bugarić, U. (2023). Importance of offline filtration system use. https://openalex.org/W7019828662 [Google Scholar] [Crossref]

7. Novak, N., Jelovčan, R., & Majdič, F. (2021). Development of portable filtration unit with self-diagnostics for industrial use. Proceedings of the 18th International Conference on Fluid Power Technologies (Fluid Power Net International). https://doi.org/10.18690/978-961-286-513-9.21 [Google Scholar] [Crossref]

8. Sawczuk, W., Kołodziejski, S., & Jüngst, M. (2025). Test verification of the condition of hydraulic oil of construction machines following the guidelines of ISO 4406 and NAS 1638. Diagnostyka. https://doi.org/10.29354/diag/208882 [Google Scholar] [Crossref]

9. Kołodziejski, S., Bartkowiak, A., & Sawczuk, W. (2024). The concept of microfiltration of hydraulic oil in rail vehicles. Rail Vehicles, 2024(2). https://doi.org/10.53502/rail-192525 [Google Scholar] [Crossref]

10. Kołodziejski, S., & Sawczuk, W. (2025). Methodology for diagnosing hydraulic oil in production machines with the additional use of microfiltration. Open Engineering, 15(1). [Google Scholar] [Crossref]

11. https://doi.org/10.1515/eng-2025-0115 [Google Scholar] [Crossref]

12. Wang, Q. (2008). The contamination balance and control of hydraulic systems. [Google Scholar] [Crossref]

13. https://openalex.org/W2366032633 [Google Scholar] [Crossref]

14. Randis, R., & Na’ali, S. (2016). Analysis of Fe reduction in RH and LH final-drive lubricant of HD 785-7 at PT Petrosea Tbk, Gunung Bayan Site, East Kalimantan, using a Kidney Loop process. JTT (Jurnal Teknologi Terpadu), 4(1). https://doi.org/10.32487/jtt.v4i1.120 [Google Scholar] [Crossref]

15. Alrazzak, F., & Mahyuda, J. (2021). Maintenance and repair of the hydraulic system on a Mitsubishi Fuso 190 PS dump truck. [Google Scholar] [Crossref]

16. Assagaf, I., Nisrina, S., & Subarkah, R. (2024). The effect of using a Kidney Loop filter on the quality of B35 biodiesel renewable fuel. [Google Scholar] [Crossref]

17. Oil contamination analysis of a Genie GS-1930 E-Drive scissor lift at PT X Gresik. (2025). J-Mesin, 3(2), 1–5. [Google Scholar] [Crossref]

18. Widya, R. N. Fauzi. (2020). Design and construction of an oil-flushing machine, 06(1), 15–26. [Google Scholar] [Crossref]

Metrics