Design and Evaluation of a Low-Cost IoT Indoor Air Quality Monitoring Prototype for Early Hazard Detection and Alerting

Authors

Anis Niza Ramani

Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Melaka (Malaysia)

Kiang Zheng Yu

Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Melaka (Malaysia)

Kyairul Azmi Baharin

Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Melaka (Malaysia)

Aine Izzati Tarmizi

Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Melaka (Malaysia)

Article Information

DOI: 10.51244/IJRSI.2026.1315PH00195

Subject Category: Public Health

Volume/Issue: 13/15 | Page No: 3847-3854

Publication Timeline

Submitted: 2026-10-18

Accepted: 2026-10-23

Published: 2026-11-03

Abstract

Affordable indoor environmental monitors provide practical potential for continuous exposure tracking and timely hazard notification in resource-constrained environments such as schools, offices, and households. However, deploying low-cost prototypes for early hazard alerting requires distinguishing functional system actuation from calibrated analytical measurement. This study evaluates the design, sensor acquisition behavior, and threshold-driven notification logic of an Internet of Things (IoT) indoor air quality monitoring prototype. The hardware architecture integrates an Arduino UNO and ESP32 microcontroller paired with a DHT22 temperature and humidity sensor, an MQ135 metal-oxide semiconductor gas sensor for volatile chemical vapors, and a GP2Y1010AU0F optical dust sensor for airborne particulates. The prototype was tested across baseline conditions and six simulated indoor exposure scenarios: elevated heat, high moisture, medicated oil vapor, incense combustion, adhesive solvent vapor, and smoke particulates. Baseline readings were 32.3 °C, 62.3% relative humidity, 1.20 for the gas response indicator, and 9.1 for the dust response indicator. Thermal and moisture stimuli drove temperature and relative humidity to 37.2 °C and 85.9%, respectively. Gas response indicators increased to 3.13, 6.59, and 4.15 under medicated oil, incense, and glue exposures, while smoke exposure elevated the dust response indicator to 35.5. Across all six exposure cases, the automated relay reliably engaged ventilation fans, and four scenarios exceeding upper setpoints initiated local auditory alarms and remote cloud-based mobile alerts. While low-cost sensors exhibit non-linearities, uncalibrated scaling, and cross-sensitivities that preclude direct clinical exposure grading, the prototype demonstrates reliable threshold-driven functional execution. These findings support the viability of accessible IoT systems as early-warning risk communication tools, provided they are supported by secondary reference calibration and qualitative risk framing.

Keywords

Indoor air monitoring, low-cost sensors, threshold analysis, Internet of Things, early hazard alerting

Downloads

References

1. Boro, K., Sumer, L., Tyngkan, M., Mandal, R., Choudhury, N., & Das, P. (2024). IoT enabled active bio filter for indoor air quality enhancement. In Proceedings of the International Conference on Signal Processing and Computer Vision (SIPCOV-2023) (pp. 351–367). Atlantis Press. [Google Scholar] [Crossref]

2. https://doi.org/10.2991/978-94-6463-529-4_32 [Google Scholar] [Crossref]

3. Clements, A. L., Griswold, W. G., Abhijit, R. S., Johnston, J. E., Herting, M. M., Thorson, J., Collier-Oxandale, A., & Hannigan, M. (2017). Low-cost air quality monitoring tools: From research to practice (a workshop summary). Sensors, 17(11), Article 2478. https://doi.org/10.3390/s17112478 [Google Scholar] [Crossref]

4. Jo, J., Jo, B., Kim, J., Kim, S., & Han, W. (2020). Development of an IoT-based indoor air quality monitoring platform. Journal of Sensors, 2020, Article 8749764, 1–14. [Google Scholar] [Crossref]

5. https://doi.org/10.1155/2020/8749764 [Google Scholar] [Crossref]

6. Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., Gao, J., Hagler, G. S. W., Jayaratne, R., Kumar, P., Lau, A. K. H., Louie, P. K. K., Mazaheri, M., Ning, Z., Motta, N., … Williams, R. (2018). Applications of low-cost sensing technologies for air quality monitoring and exposure assessment: How far have they gone? Environment International, 116, 286–299. https://doi.org/10.1016/j.envint.2018.04.018 [Google Scholar] [Crossref]

7. Petrică, S.-M., Făgărășan, I., Arghira, N., & Munteanu, I. (2026). Real time IoT low-cost air quality monitoring system. Sustainability, 18(2), Article 1074. https://doi.org/10.3390/su18021074 [Google Scholar] [Crossref]

8. Saini, J., Dutta, M., & Marques, G. (2020). A comprehensive review on indoor air quality monitoring systems for enhanced public health. Sustainable Environment Research, 30, Article 6. [Google Scholar] [Crossref]

9. https://doi.org/10.1186/s42834-020-0047-y [Google Scholar] [Crossref]

10. Sharp Corporation. (2006). GP2Y1010AU0F: Compact optical dust sensor (Datasheet No. E4-A0150 1EN). Sharp Corporation. [Google Scholar] [Crossref]

11. https://global.sharp/products/device/lineup/data/pdf/datasheet/gp2y1010au_e.pdf [Google Scholar] [Crossref]

12. Szulczyński, B., & Gębicki, J. (2017). Currently commercially available chemical sensors employed for detection of volatile organic compounds in outdoor and indoor air. Environments, 4(1), Article 21. [Google Scholar] [Crossref]

13. https://doi.org/10.3390/environments4010021 [Google Scholar] [Crossref]

14. Taştan, M. (2022). A low-cost air quality monitoring system based on Internet of Things for smart homes. Journal of Ambient Intelligence and Smart Environments, 14(5), 351–374. https://doi.org/10.3233/AIS-210458 [Google Scholar] [Crossref]

15. Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015). Laboratory evaluation and calibration of three low-cost particle sensors for particulate matter measurement. Aerosol Science and Technology, 49(11), 1063–1077. https://doi.org/10.1080/02786826.2015.1100710 [Google Scholar] [Crossref]

16. Winsen Electronics Technology Co., Ltd. (2021). Air quality gas sensor (Model MQ135) manual (Version 1.6). Zhengzhou Winsen Electronics Technology Co., Ltd. [Google Scholar] [Crossref]

17. https://www.winsen-sensor.com/d/files/manual/mq135.pdf [Google Scholar] [Crossref]

18. Yu, Y., Gola, M., Settimo, G., Buffoli, M., & Capolongo, S. (2024). Feasibility and affordability of low-cost air sensors with Internet of Things for indoor air quality monitoring in residential buildings: Systematic review on sensor information and residential applications, with experience-based discussions. Atmosphere, 15(10), Article 1170. https://doi.org/10.3390/atmos15101170 [Google Scholar] [Crossref]

19. Yun, J., Ahn, S., Kim, H., Shin, S., & Seo, Y.-D. (2026). Low-cost sensor calibration for indoor air quality monitoring: A dataset, evaluation scenarios, and a lightweight model (arXiv Preprint arXiv:2610.11236). arXiv. https://arxiv.org/abs/2610.11236 [Google Scholar] [Crossref]

Metrics

Views & Downloads

Similar Articles