Removal of Retained Broken Distal Femoral Nail Using a Corkscrew in a Resource-Constrained Setting. A Case Report.
Authors
Department of Orthopaedics and Trauma, University of Nigeria Teaching Hospital, Ituku/Ozalla, Enugu; Department of Surgery, Godfrey Okoye University, Enugu (Nigeria)
Department of Orthopaedics, National Orthopaedic Hospital, Enugu (Nigeria)
Department of Plastic and Reconstructive Surgery, National Orthopaedic Hospital, Enugu (Nigeria)
Division of Plastic Surgery, Department of Surgery, Alex Ekwueme University Teaching Hospital, Abakaliki, Ebonyi State; Department of Surgery, Alex Ekwueme University, Ndufu-Alaike, Ikwo, Ebonyi State (Nigeria)
Department of Nursing Sciences, Southern Delta University, Ozoro, Delta State (Nigeria)
Department of Surgery, Godfrey Okoye University, Enugu; Department of Orthopaedics, National Orthopaedic Hospital, Enugu (Nigeria)
Department of Nursing Services, National Orthopaedic Hospital, Enugu (Nigeria)
Okonkwo, Chukwuebuka Augustine
Department of Orthopaedics and Trauma, University of Nigeria Teaching Hospital, Ituku/Ozalla, Enugu (Nigeria)
Article Information
DOI: 10.51244/IJRSI.2026.1304000130
Subject Category: Health Science
Volume/Issue: 13/4 | Page No: 1463-1470
Publication Timeline
Submitted: 2026-04-12
Accepted: 2026-04-18
Published: 2026-05-06
Abstract
Background: Implant failure following intramedullary nailing of femoral shaft fractures, though uncommon, presents a significant surgical challenge, particularly when the distal fragment of a broken nail is retained within the medullary canal. Conventional extraction techniques are often technically demanding, may require specialized instruments, and can increase operative morbidity. This challenge is further amplified in resource-constrained settings where advanced tools may not be readily available.
Case Presentation: We report the case of a 56-year-old male who presented with a 7-month history of right thigh pain, deformity, and abnormal mobility following previous surgical interventions for femoral shaft fracture. Radiographic evaluation revealed atrophic nonunion with broken intramedullary implants (Kuntscher nail and Rush pin). During surgery, conventional extraction techniques successfully removed the proximal components; however, the distal fragment proved difficult to retrieve. A corkscrew device, obtained from a hip arthroplasty set, was introduced into the lumen of the retained nail fragment, achieving secure purchase and enabling controlled extraction. This was followed by exchange intramedullary nailing and bone grafting.
Intervention: Minimally invasive extraction of the retained distal nail fragment using a corkscrew technique, followed by definitive fixation with interlocking intramedullary nailing and autologous bone grafting.
Outcome: Postoperative recovery was uneventful. The patient commenced early mobilization and progressed from non-weight bearing to full weight bearing by 12 weeks. Follow-up radiographs demonstrated satisfactory callus formation, and the patient reported resolution of pain, restoration of limb length, and return to functional ambulation.
Conclusion: The corkscrew extraction technique is a simple, cost-effective, and minimally invasive method for removing retained distal fragments of broken intramedullary femoral nails. It is particularly valuable in resource-limited settings and should be considered a reliable alternative when conventional extraction methods fail.
Keywords
Intramedullary nail, femoral shaft fracture
Downloads
References
1. Al-Hadithy, N., Sewell, M. D., Bhavikatti, M., & Gikas, P. D. (2017). Radiation exposure during orthopaedic procedures: A systematic review. Bone & Joint Journal, 99-B(7), 915–922. [Google Scholar] [Crossref]
2. Brenner, J., Joiner, J., Schweller, E., Ren, E., Nasr, K., & Vaidya, R. (2024). Femoral intramedullary nail extraction using the kissing nail technique. Orthopedic Research and Reviews, 8, e355. [Google Scholar] [Crossref]
3. Brewster, N. T., Ashcroft, G. P., & Scotland, T. R. (1995). Extraction of broken intramedullary nails—An improvement in technique. Injury, 26(4), 286–287. https://doi.org/10.1016/0020-1383(95)00026-K. [Google Scholar] [Crossref]
4. Brumback, R. J., & Virkus, W. W. (2000). Intramedullary nailing of the femur: Reamed versus nonreamed. Journal of the American Academy of Orthopaedic Surgeons, 8(2), 83–90. https://doi.org/10.5435/00124635-200003000-00002 [Google Scholar] [Crossref]
5. Calori, G. M., Phillips, M., Jeetle, S., Tagliabue, L., & Giannoudis, P. V. (2019). Classification of non-union: Need for a new scoring system? Injury, 49(Suppl 2), S59–S63. [Google Scholar] [Crossref]
6. Chen, W., Wang, P., & Wen, F. (2020). Surgical outcomes in complex intramedullary nail removal. Journal of Orthopaedic Surgery and Research, 15, 210. [Google Scholar] [Crossref]
7. Elsoe, R., Larsen, P., Nielsen, N. P. H., Swenne, J., Rasmussen, S., & Østgaard, S. E. (2022). Population-based epidemiology of femoral shaft fractures. Injury, 53(1), 83–89. https://doi.org/10.1016/j.injury.2021.10.012 [Google Scholar] [Crossref]
8. Giannoudis, P. V., Einhorn, T. A., Marsh, D., & Schmidmaier, G. (2017). The diamond concept—Open questions. Injury, 48(Suppl 1), S3–S5. https://doi.org/10.1016/S0020-1383(17)30194-1 [Google Scholar] [Crossref]
9. Hak, D. J., & McElvany, M. (2008). Removal of broken hardware. Journal of the American Academy of Orthopaedic Surgeons, 16(2), 113–120. https://doi.org/10.5435/00124635-200802000-00006 [Google Scholar] [Crossref]
10. Hii, J. L., Fang, C. J., Evans, S. L., & Schuch, M. (2025). Removal of a broken femoral intramedullary nail. Case Reports in Orthopedics, 2025, 6220126. [Google Scholar] [Crossref]
11. Kose, O., Durakbasa, M. O., Islam, N. C., & Kilicaslan, O. F. (2017). A novel technique for removal of broken intramedullary nails. Acta Orthopaedica et Traumatologica Turcica, 51(3), 234–238. https://doi.org/10.1016/j.aott.2017.03.005 [Google Scholar] [Crossref]
12. Kumar, R., Singh, R., & Sharma, A. (2018). Removal techniques of broken femoral nails. Injury, 49(8), 1423–1428.Magu, N. K., Sharma, A. K., & Singh, R. (2004). Extraction of broken femoral nail. Injury, 35(12), 1322–1323. [Google Scholar] [Crossref]
13. Mauffrey, C., Hak, D. J., Martin, M. P., & Hammerberg, E. M. (2016). Complications and management of intramedullary nailing of femoral shaft fractures. Journal of the American Academy of Orthopaedic Surgeons, 24(9), 645–653. https://doi.org/10.5435/JAAOS-D-15-00393 [Google Scholar] [Crossref]
14. Mauffrey, C., Herbert, B., Young, H., Wilson, M. L., Hake, M., & Stahel, P. F. (2020). The role of intramedullary nailing in femoral shaft fractures. EFORT Open Reviews, 5(5), 239–247. https://doi.org/10.1302/2058-5241.5.190046 [Google Scholar] [Crossref]
15. Metsemakers, W. J., Morgenstern, M., McNally, M. A., Moriarty, T. F., McFadyen, I., Scarborough, M., Athanasou, N. A., Ochsner, P. E., Kuehl, R., Raschke, M., & Verhofstad, M. H. J. (2018). Fracture-related infection: A consensus on definition. Injury, 49(3), 505–510. https://doi.org/10.1016/j.injury.2017.08.040 [Google Scholar] [Crossref]
16. Middleton, R. G., & McNab, I. (1980). Extraction of broken femoral intramedullary nails using a corkscrew device. Clinical Orthopaedics and Related Research, 147, 150–153. [Google Scholar] [Crossref]
17. Mohammed, A., Eze, K. C., & Nwadiaro, H. C. (2018). Implant removal in low-resource settings. African Journal of Trauma, 7(2), 45–50. [Google Scholar] [Crossref]
18. Pongsamakthai, W., Apivatthakakul, T., & Sangkomkamhang, T. (2016). T-reamer technique. Journal of Clinical Orthopaedics and Trauma, 7(Suppl 1), 22–26. [Google Scholar] [Crossref]
19. Poutoglidou, F., & Krkovic, M. (2022). Broken nail removal technique. Archives of Bone and Joint Surgery, 10(11), 982–985. [Google Scholar] [Crossref]
20. Seyhan, M., Unay, K., Sener, N., & Karatosun, V. (2018). Removal of broken intramedullary femoral nails: A technical note and review of literature. European Journal of Orthopaedic Surgery & Traumatology, 28(5), 935–942. https://doi.org/10.1007/s00590-018-2147-5. [Google Scholar] [Crossref]
21. Sharma, A. J., & Mahajan, A. (2013). Simple technique for removal of distal broken femoral nail using a corkscrew. Orthopaedics & Traumatology: Surgery & Research, 99(3), 379–382. https://doi.org/10.1016/j.otsr.2012.11.012 [Google Scholar] [Crossref]
22. Sharma, V., & Yadav, S. S. (2020). Comparative evaluation of extraction techniques. Journal of Orthopaedic Case Reports, 10(5), 34–39. [Google Scholar] [Crossref]
23. Whalley, H., & Thomas, G. (2009). A review of techniques for the removal of broken intramedullary nails. Injury, 40(6), 595–599. https://doi.org/10.1016/j.injury.2008.10.030 [Google Scholar] [Crossref]
24. Wu, C. C. (1996). Treatment of femoral shaft aseptic nonunion associated with broken nail. Journal of Trauma, 40(4), 633–638. [Google Scholar] [Crossref]
25. Zhang, Q., Gao, F., Zhou, D., & Ren, Y. (2021). Techniques and pitfalls in removal of broken intramedullary nails: A systematic review. BMC Musculoskeletal Disorders, 22, 1021. [Google Scholar] [Crossref]
26. Zhang, Q., Liu, H., & Li, Y. (2021). Challenges in nail removal. Orthopaedics & Traumatology: Surgery & Research, 107(3), 102779. [Google Scholar] [Crossref]
Metrics
Views & Downloads
Similar Articles
- Measuring Waste of Patient Time in Health Care at Non-Digitized Hospital: An Observational Study in Bangabandhu Sheikh Mujib Medical University, Bangladesh
- Reaffirming Clinical Confidence in Atorvastatin Therapy: A Digital Outreach Case Study from Tamil Nadu, India
- Clinical Manifestations and Therapeutic Response in a Patient with Hypothyroidism: A Case Report
- Eranda (Ricinus Communis) In Gridhrasi (Sciatica): Classical Rationale, Pharmacology and Clinical Evidence- A Narrative Literature Review
- Magnetotherapy in Pain Management: Mechanisms, Clinical Applications, and Future Perspectives – A Review