International Journal of Research and Scientific Innovation (IJRSI)

Submission Deadline-22nd November 2024
November 2024 Issue : Publication Fee: 30$ USD Submit Now
Submission Deadline-05th December 2024
Special Issue on Economics, Management, Sociology, Communication, Psychology: Publication Fee: 30$ USD Submit Now
Submission Deadline-20th November 2024
Special Issue on Education, Public Health: Publication Fee: 30$ USD Submit Now

Driving Sustainable Energy Dispatch for Remote Communities Using Levy Flight Salp Swarm Algorithm

  • Benjamin O. Ajayi
  • Anthony Ibe
  • Boniface A. Oriji
  • Toyin O. Odutola
  • 1256-1271
  • Sep 15, 2024
  • Education

Driving Sustainable Energy Dispatch for Remote Communities Using Levy Flight Salp Swarm Algorithm

Benjamin O. Ajayi, Anthony Ibe, Boniface A. Oriji, Toyin O. Odutola

Emerald Energy Institute, University of Port Harcourt, Nigeria

DOI: https://doi.org/10.51244/IJRSI.2024.1108096

Received: 08 August 2024; Accepted: 13 August 2024; Published: 15 September 2024

ABSTRACT

This study evaluates three energy dispatch algorithms to find the best way to improve hybrid energy systems in rural areas: load following (LF), cycle charging (CC), and a novel customized strategy (CS). The study examined solar and wind resources as well as projected patterns of energy consumption with a particular focus on Bambur village in Taraba State, Nigeria.  The Levy Flight Salp Swarm Algorithm (LFSSA) was used in the study to assess system configurations for each method, accounting for battery storage, wind turbines, diesel generators, and photovoltaic (PV) arrays. The most cost-effective and efficient approach was determined to be the Customized Strategy (CS), which produced the lowest Net Present Cost (NPC) of $ 1,959,100 and Levelized Cost of Energy (LCOE) of $ 0.119/kWh. The Load Following (LF) technique had the highest costs at $ 2,204,736.10 and $ 0.134/kWh, while the Cycle Charging (CC) method had intermediate costs with an NPC of $ 2,083,770 and an LCOE of $ 0.127/kWh. With a 580-kWh battery bank, a 10 kW wind turbine, 332 kW of PV capacity, and a 78 kW diesel generator, the CS approach showed better component sizing balance. The trade-offs between energy output, storage, and backup power in real-time were optimized using this design. Sensitivity analysis revealed that increasing interest rates from 10% to 18% led to a rise in LCOE, while diesel cost fluctuations showed a non-monotonic impact on LCOE, peaking at $ 0.79/L before declining due to increased reliance on renewable sources and storage. CS strategy’s balance of investment and efficiency makes it ideal for remote energy management, offering key insights for rural electrification.

Keywords: Hybrid Energy System (HES), Dispatch Strategies, Levelized Cost of Energy (LCOE), Net Present Cost (NPC), Levy Flight Salp Swarm Algorithm (LFSSA)

INTRODUCTION

Nigeria’s rich cultural diversity and natural resources are overshadowed by challenges like rural electricity shortages and the need for sustainable development. These issues, critical to national development, impede daily life and economic growth. Many rural areas lack reliable electricity, affecting education, healthcare, and industries, thereby perpetuating poverty and underdevelopment [1].

The critical need for power generation based on renewable energy (RE) to meet future energy issues is highlighted by the world’s rapidly diminishing fossil fuel sources. The use of fossil fuels increases emissions significantly, underscoring the need of using renewable energy sources like wind and solar power. Hybrid energy systems (HES) have made it feasible and efficient to integrate these dispersed renewable energy sources [2].

Stand-alone HES can be a useful option for decentralized power generation and distribution in remote locations, especially when combined with diesel backup. Renewable energy sources like wind and solar power are especially useful in this regard. By utilizing the plentiful and sustainable energy derived from natural sources, these systems lessen dependency on fossil fuels and encourage environmental sustainability [1], [2], [3], [4], [5], [6], [7], [8], [9], [10]. Rural areas face challenges such as poor road access, isolated locations, and high supply costs, making grid extension impractical. Diesel generators are often used but come with high costs, maintenance needs, and pollution [11]. Nigeria’s ample renewable resources—solar and wind—offer an alternative. Studies advocate for solar PV, wind, and hybrid systems to provide sustainable and efficient power [1], [2], [3], [4], [5], [6], [7], [8], [9], [10]. Successful dispatch strategies are essential for optimizing these systems, reducing costs, and enhancing reliability [12], [13], [14].

Energy control strategies in hybrid energy systems optimize resource utilization, reduce costs, and enhance reliability. They improve efficiency, extend component lifespans, and promote environmental sustainability. These strategies drive technological advancements, making renewable energy more viable and encouraging wider adoption of hybrid systems. Cycle Charging (CC) maximizes battery use by charging during low demand or high renewable generation and discharging during peaks, increasing renewable energy use and efficiency. Load Following (LF) dynamically adjusts power generation to demand changes, optimizing renewables and grid stability.

Several studies have compared different dispatch strategies, some with grid connections and others with standalone grids. These studies examined existing strategies like LF and CC, along with other dispatch strategies [2], [4], [5], [6], [7], [8], [9], [10], [15], [16], [17], [18]

Most papers focused on performance parameters such as NPC and COE [2], [4], [5], [6], [7], [8], [9], [10], [15], [16], [17], [18], while some included CO2 emissions as a performance parameter [2], [7], [9], [15], [17], [19]

This study introduces a Customized Strategy (CS) that combines the benefits of LF and CC by optimizing battery charging and discharging based on projected load demands and anticipated renewable energy generation. A planned PV/Wind/Diesel/Battery HES designed to electrify the off-grid rural area of Bambur, Taraba State, Northern Nigeria, is analyzed, which was developed in MATLAB. The approach uses the Levy Flight Salp Swarm Algorithm (LFSSA) to determine which of the three dispatch strategies—LF, CC, and CS—is the best. This algorithm’s main goal is to maximize the share of renewable energy while lowering the Levelized Cost of Energy (LCOE) and Net Present Cost (NPC).

METHODOLOGY

This section presents the methodological framework for developing and optimizing the HES, starting with mathematical models of energy sources. This is followed by the description of the study area.

Energy Source Modeling

Mathematical modeling is vital for designing, optimizing, and assessing hybrid energy systems. It helps predict power flow, determine optimal component sizes, and integrate solar, wind, and storage technologies, ensuring efficient, reliable, and economically viable systems. This approach advances sustainable energy by enhancing system performance and grid integration.

Equation 1: PV Array Model

$$ P_{PV} = Y_{PV} \cdot f_{PV} \cdot \frac{G_T}{G_{TST}} \left(1 + \alpha_P \cdot (T_C – T_{CST})\right) $$

Where:

  • \( Y_{PV} \): PV array’s rated capacity in kW
  • \( f_{PV} \): PV derating factor (%)
  • \( G_T \): Solar radiation currently reaching the PV array (kW/m²)
  • \( G_{TST} \): Incident radiation under standard conditions (typically 1 kW/m²)
  • \( T_C \): Current PV cell temperature (°C)
  • \( \alpha_P \): Temperature coefficient of power (%)
  • \( T_{CST} \): PV cell temperature under standard conditions

Equation 2: Wind Turbine Power Production

$$ P_{WDT}(t) =
\begin{cases}
0 & \text{if } v_{hub} < v_{cut-in} \text{ or } v_{hub} \geq v_{cut-out} \\
P_{WDT-r} \left(\frac{v_{hub}^3 – v_{cut-in}^3}{v_R^3 – v_{cut-in}^3}\right) & \text{if } v_{cut-in} \leq v_{hub} < v_R \\
P_{WDT-r} & \text{if } v_R \leq v_{hub}(t) < v_{cut-out}
\end{cases}
$$

Equation 3: Wind Profile Power Law

$$ V_{hub}(t) = V_{ref}(t) \left(\frac{h_{hub}}{h_{ref}}\right)^{\alpha} $$

Equation 4: Battery Storage System Model

$$ E_{BSS}(t) = E_{BSS}(t-1)(1 – \sigma) + E_{excess} \eta_{BSS} $$

$$ E_{BSS}(t) = E_{BSS}(t-1)(1 – \sigma) – E_{deficit} $$

  • \( \sigma \): Battery self-discharge rate
  • \( E_{excess} \): Excess energy stored
  • \( \eta_{BSS} \): Battery charging efficiency
  • \( E_{deficit} \): Deficit energy

Equation 5: State of Charge (SOC)

$$ SOC(t) = SOC(t-1) + \frac{\sum_{i=1}^{N} P_i(t) – P_{load}(t)}{V_{BSS} C_{BSS}} $$

  • \( N \): Number of generator units
  • \( P_i(t) \): Power output of generator \( i \) at time \( t \)
  • \( P_{load}(t) \): Load’s power requirement at time \( t \)
  • \( V_{BSS} \): Battery voltage
  • \( C_{BSS} \): Battery capacity

Equation 6: Diesel Generator Fuel Consumption

$$ C_{f-DG} = \alpha_{DG} \cdot P_{DG}(t) + \beta_{DG} \cdot P_{rated-DG} $$

  • \( C_{f-DG} \): Diesel generator fuel consumption
  • \( P_{DG}(t) \): Average power supplied by DG at time \( t \)
  • \( P_{rated-DG} \): Rated power output of DG
  • \( \alpha_{DG}, \beta_{DG} \): Fuel consumption coefficients

Equation 7: Rectifier Model

$$ P_{Rect-o}(t) = P_{Rect-i}(t) \cdot \eta_{Rect} $$

Equation 8: Inverter Model

$$ P_{Invt-o}(t) = P_{Invt-i}(t) \cdot \eta_{Invt} $$

Equation 9: Levelized Cost of Energy (LCOE)

$$ LCOE = \frac{C_{INT} + C_{OM} + C_{REP} – S_{SAL} \cdot CRF}{E_{gen}(t)} $$

Equation 10: Capital Recovery Factor (CRF)

$$ CRF = \frac{r(1 + r)^n}{(1 + r)^n – 1} $$

Equation 11: Annualized Capital Cost

$$ C_{INT} = \sum_{j=1}^{N} C_{INT_j} $$

Equation 12: Operations and Maintenance Cost

$$ C_{OM} = \sum_{j=1}^{N} C_{OM_j} $$

Equation 13: Replacement Cost

$$ C_{REP} = \sum_{j=1}^{N} C_{REP_j} (1 + r)^{t_i} $$

Equation 14: Salvage Value

$$ C_{SAL} = \sum_{j=1}^{N} C_{INT_j} \times \left(1 – \frac{t_{sys}}{L_i}\right) $$

Cost and Lifespan Notations

\( C_{INTj} \) is the initial cost of component \( j \).
\( t_{sys} \) is the entire operational lifetime of the system.
\( L_i \) is the expected lifespan of component \( j \).

Modelling of HES

This research introduces a novel energy dispatch strategy named the Customized Strategy (CS) for optimizing power dispatch in hybrid energy systems. The CS prioritizes renewable energy sources by leveraging the strengths and mitigating the weaknesses of two existing strategies: LF and CC.

The study uses LFSSA to optimize the system setup using the MATLAB simulation tool. Comparison is made between the results of different energy dispatch systems, such as LF, CC, and Customized Strategy (CS). In order to minimize the system’s COE and NPC while maintaining adherence to predetermined operational limits, the ideal number of photovoltaic (PV) modules, wind turbines, battery banks, and diesel generator capacity must be determined.

Customized Strategy (CS) offers superior performance over cycle charging (CC) and load following (LF) by dynamically adapting to changing conditions. It uses intelligent prediction and state of charge (SOC) feedback to optimize fuel economy and battery sustainability. Unlike static CC, which lacks adaptability, and LF, which doesn’t optimize for efficiency, CS handles the complexities of hybrid energy systems more effectively by balancing load demands and renewable variability.

Hybrid Energy System Components

The analysis assumes a system lifetime of 20 years, and the system components (PV modules, wind turbines, diesel generator, and battery storage) are defined in Table 3.1.

Table I - The System Components 

Table I – The System Components

Optimization Techniques

The Flight Levy Salp Swarm Algorithm (FLSSA) a novel optimization technique that combines the concepts of Lévy flight and the Salp Swarm Algorithm (SSA) is employed for the studies.

SSA is a cutting-edge optimization method modeled after nature that mimics the swarming behavior of salps in the ocean. The key aspects of the SSA are:

  1. Initialization: As shown in Equation (15), the method begins by initializing the salp positions within the search space boundaries at random.
  2. Salp Categorization: A leader and followers comprise the salp population. The swarm is directed toward the food source (optimal solution) by the leader salp.
  3. Position Update: The leader’s position is adjusted, as in Equation (16), based on random coefficients that balance exploration and exploitation and the current location of the food supply.
  4. The followers’ positions are updated according to the location of their previous salp using Newton’s law of motion.
  5. Fitness Evaluation: The fitness (objective function value) of each salp position is evaluated.
  6. Iteration: Steps 3–4 are repeated until the termination criteria (such as the maximum number of iterations) are met.

The goal of the SSA is to replicate the coordinated and cooperative movement of actual salp swarms in the water in order to effectively search the search space and converge to the global optimum. When compared to other metaheuristic approaches, the algorithm’s performance on a variety of optimization problems has shown promise.

Key Equations

Equation (15):
\[
X_p = x_{11}x_{12}…x_{1n}x_{21}x_{22}…x_{2n}…x_{d1}x_{d2}…x_{dn}
\]

Equation (16):
\[
x_{i1} =
\begin{cases}
z_1 + a_1(ub_p – lb_p) a_2 + lb_p & \text{if } a_3 \geq 0 \\
z_1 + a_1(ub_p – lb_p) a_2 + lb_p & \text{if } a_3 < 0
\end{cases}
\]

Equation (17):
\[
a_1 = 2 e^{-4\frac{l}{L}}
\]

Equation (18):
\[
x_{pj} = \frac{1}{2} \lambda t^2 + \delta_o t
\]

Equation (19):
\[
x_{pj} = \frac{1}{2}(x_{pj} + x_{pj-1})
\]

Equation (20):
\[
x_{pj} =
\begin{cases}
l_j & \text{if } x_{ij} \leq l_j \\
u_j & \text{if } x_{ij} \leq u_j \\
x_{pj} & \text{otherwise}
\end{cases}
\]

Levy Flight Equation (21):
\[
L_s \sim \frac{1}{s^{1+\beta}}
\]
where \( 1 < \beta \leq 3 \).

Equation (22):
\[
x_{ij} = x_{ij} + \alpha L(s)
\]

The FLSSA leverages the Levy flight strategy along with the swarming characteristic of salps to enhance both exploration and exploitation in the search space. The algorithm divides the salp population into leaders and followers, with the leader leading the swarm and the followers trailing behind. The leader’s position is updated using an algorithm that accounts for the location of the food source, search space limitations, and random factors. The followers’ positions are updated using Newton’s law of motion. The Levy flight strategy introduces long jumps that help the algorithm escape local optima. This approach balances exploration and exploitation, making it suitable for various optimization problems in engineering design, machine learning, and resource allocation.

RESULT AND DISCUSSION

The outcomes of the estimated energy demand and renewable energy data for the study area are displayed in charts, followed by the use of LFSSA to compare various energy dispatch methods, such as Customized Strategy (CS), Cycle Charging (CC), and Load Following (LF).

Study Area and Population of the Study

The study examines the potential for renewable energy solutions in Bambur, a village situated in Taraba State, Nigeria. Bambur lies at approximately 9° 20′ 59″ North latitude and 11° 2′ 41″ East longitude. A part of Central Bambur is the area under study, encompasses roughly 200 residences, a primary healthcare center, a public primary school, and a bustling commercial hub.

Figure 1 - Location of the study area (Bambur)

Figure 1 – Location of the study area (Bambur)

The population is estimated at around 1,000, comprising regular dwellers and others who conduct business at the hub. The majority of the residents are engaged in agricultural activities. Similar to many villages in the region, Bambur currently lacks access to the national electricity grid.

The wind and sun irradiation data utilized in this study was obtained by the National Aeronautics and Space Administration (NASA). The estimated energy demand for Bambur were determined through a combined approach of data collection via questionnaires and subsequent validation by comparing the obtained data with the average energy demand of a typical village in Northern Nigeria. This multi-pronged approach ensured the accuracy and representativeness of the energy demand estimations for the village.

The average yearly solar radiation and wind speed, as determined by the study’s analysis of 8760 hours of village data, are 5.61 kWh/m2/day and 5.12 m/s, respectively. The daily load demand curve for Bambur Village is shown in Figure 3.2. The average daily electrical load demand is 482 kWh, with an anticipated peak daily load demand of 26.75 kW. Energy use peaks twice daily: mornings (5-8 AM) and evenings (7-10 PM), likely due to typical daily routines. To enable a comparative study of the patterns of energy consumption, the load demand is shown for the wet season and the dry season. The dry season experiences significantly higher demand, primarily driven by cooling needs and extended business hours compared to the wet season.

Figure 2 - Daily load demand in Bambur Village

Figure 2 – Daily load demand in Bambur Village

Monthly wind speed in Bambur Village

Figure 3 highlights the wind speed data for Bambur, crucial for evaluating wind energy potential. Wind speeds peak at around 7 m/s in January and 6.5 m/s in December, indicating favorable conditions for wind energy generation. However, speeds drop to around 4 m/s in June and July, necessitating energy storage or additional sources to maintain a reliable energy supply.

Figure 3 – Wind Speed in Bambur

Figure 3 – Wind Speed in Bambur

Monthly solar radiation in Bambur Village

Figure 4 presents monthly solar radiation data for Bambur, crucial for assessing solar photovoltaic (PV) system performance. January and December show high solar radiation at around 5.7 kWh/m², and from February to April, levels remain consistently high at 5.9-6.5 kWh/m². May and June see a slight dip to about 5 kWh/m², while July and August exhibit the lowest levels at 4-4.5 kWh/m². Radiation increases again from September, peaking at 6.2 kWh/m² in November.

Figure 3 – Wind Speed in Bambur

Figure 4 – Solar Radiation in Bambur

Hybrid Energy System

This analysis compares three strategies for a HES: LF, CC and CS. The components evaluated are Photovoltaic (PV) systems, Wind Turbines (WT), Battery Storage Systems (BSS), and Diesel Generators (DG) in Figure 5.

Figure 5 – Hybrid Energy System Components (PV, WT, DG & BSS)

Figure 5 – Hybrid Energy System Components (PV, WT, DG & BSS)

1) Photovoltaic (PV) System: The Load Following strategy prioritizes real-time energy with 353 kW PV capacity. Cycle Charging, at 319 kW, relies more on storage and diesel. The Customized Strategy, with 332 kW, balances energy production and storage, aiming for cost efficiency and reliability.

2) Wind Turbine (WT): The consistent 10 kW wind turbine capacity across strategies suggests limited or consistent wind resources, making larger turbines unnecessary. Wind power plays a minor role compared to PV systems, and its integration isn’t influenced by operational strategy choice.

3) Battery Storage System (BSS)

Energy dispatch strategies vary in battery capacities. Cycle Charging uses the largest at 679 kWh for maximum renewable utilization and minimal diesel use. Load Following, with 495 kWh, focuses on real-time generation. The Customized Strategy balances at 580 kWh, optimizing storage and costs.

4) Diesel Generator (DG): Generator size choices reveal distinct strategies: Load Following and Customized Strategy use a larger 78 kW generator for robust backup and grid stability during peaks. Cycle Charging, with a smaller 63 kW generator and larger battery, emphasizes stored renewable energy, reducing fossil fuel use and emissions.

5) Overall System Analysis: LF prioritizes immediate demand with the largest PV capacity and generator but smallest battery, leading to higher diesel use during low solar output. CC emphasizes storage with the largest battery but smallest PV and generator, minimizing diesel consumption. CS balances components, optimizing cost, reliability, and renewable use. All strategies reflect solar-driven systems with minor wind roles, highlighting location’s solar potential and limited wind. Battery size variations emphasize storage’s importance, and generator roles vary, demonstrating system flexibility for different operational goals.

HES with Relevant Parameters

This analysis examines the relevant parameters for the three strategies in a HES: LF, CC, and Customized Strategy (CS).

Figure 6 – Initial Capital Cost

Figure 6 – Initial Capital Cost

Initial Capital Cost

The Customized Strategy (CS) has the lowest initial capital cost at $711,936.94, followed by Cycle Charging (CC) at $720,755.21 and Load Following (LF) at $821,043.72 as in Figure 6, CS system would require the least amount of upfront investment compared to the other two options.

Figure 7 – Operating Costs

Figure 7 – Operating Costs

Operating Costs

Fig. 7 indicates the operating costs with Load Following (LF) has the highest at $179,588.98, followed by Cycle Charging (CC) at $173,903.11, while the Customized Strategy (CS) has the lowest at $141,340.45. Thus, CS is the most cost-effective option for operating expenses.

Figure 8 – LCOE and NPC – Dispatch Strategies (LF, CC & CS)

Figure 8 – LCOE and NPC – Dispatch Strategies (LF, CC & CS)

Net Present Cost (NPC):

Load Following (LF) has the highest NPC at $2,204,736.10 due to larger PV and diesel investments and higher operational costs. Cycle Charging (CC) has a moderate NPC of $2,083,770.00 (Fig. 8), balancing initial investments with efficient storage use. Customized Strategy (CS) has the lowest NPC at $1,959,100.00, optimizing costs and efficiency. These values indicate CS offers the best long-term economic performance, followed by CC, with LF incurring the highest costs.

Levelized Cost of Energy (LCOE):

Load Following (LF) has the highest LCOE at $0.134/kWh, indicating low cost-efficiency. Cycle Charging (CC) improves with $0.127/kWh, using energy storage efficiently. Customized Strategy (CS) achieves the lowest LCOE at $0.119/kWh, balancing renewables, storage, and backup. CS offers the most cost-effective energy production, followed by CC, with LF being the least economical.

CO2 Emission

Figure 9 illustrates the carbon dioxide (CO2) emissions associated with three distinct algorithms: LF, CC, and CS, measured in kilograms per year. Among these, the CC algorithm exhibits the highest level of CO2 emissions, approximately 32,452 kg/year. Following closely, the LF algorithm generates emissions of 25,138 kg/year, while the CS algorithm records the lowest emissions, slightly below 24,897 kg/year.

Figure 9 – CO2 Emission

Figure 9 – CO2 Emission

Overall System Analysis:

The Customized Strategy (CS) emerges as the most cost-effective option, featuring the lowest Net Present Cost (NPC) and Levelized Cost of Energy (LCOE), as well as the least CO2 emissions. Cycle Charging (CC) offers a lower-cost option compared to LF; however, it results in the highest CO2 emissions.

Sensitivity Test

The sensitivity analysis examines how variations in fuel prices and interest rates influence the LCOE and NPC.

Figure 10 – Sensitivity with Interest Rate

Figure 10 – Sensitivity with Interest Rate

Figure 10 illustrate the sensitivity analysis demonstrates that increasing interest rates from 10% to 18% lead to a rise in the LCOE for HES. This non-linear relationship underscores the importance of strategic financial planning to manage elevated financing costs and ensure the sustainability of renewable energy projects.

Figure 10 – Sensitivity with Interest Rate

Figure 11 – Sensitivity with Diesel Cost

The sensitivity analysis of diesel costs on the LCOE for a HES as highlighted in Figure 11 shows a non-monotonic relationship, with LCOE peaking at $0.79/L before declining. This trend is influenced by the controller’s logic, which shifts reliance to battery storage and renewable energy as diesel costs rise, highlighting the importance of smart energy management.

CONCLUSION

In summary, this study offers significant insights into optimizing HES for remote settlements by evaluating LF, CC and novel CS. Focused on Bambur village in Taraba State, Nigeria, the research highlights how different dispatch methods can influence system performance, cost efficiency, and sustainability.

The findings reveal that the Customized Strategy (CS) is the most practical and affordable choice, achieving the lowest NPC of $1,959,100 and a LCOE of $0.119/kWh, outperforming both the LF and CC. The CS strategy also showcased an optimal configuration of energy components, balancing the capacities of solar, wind, battery storage, and diesel generation to maximize energy production and reliability.

Local adaptation is necessary for HES, which prioritize RE and efficiency of the batteries. Because interest rates and diesel prices fluctuate, financial planning is essential. Performance is improved via customized dispatch, which prioritizes balanced energy integration over capacity maximization.

This study advances knowledge of sustainable energy options for remote populations by showing that enhanced HES can provide dependable, reasonably priced electricity to places without grid connectivity. The promising results of the Customized Strategy pave the way for future research into adaptive energy management systems, potentially leveraging machine learning for real-time decision-making.

As global efforts to address rural electrification and transition to sustainable energy continue, this study serves as a valuable resource for policymakers, engineers, and communities aiming to implement effective energy solutions. The findings not only provide a framework for enhancing energy access in Nigeria but also offer adaptable strategies for similar challenges faced worldwide.

REFERENCES

  1. U. Emezirinwune, I. A. Adejumobi, O. I. Adebisi, and F. G. Akinboro, “Synergizing hybrid renewable energy systems and sustainable agriculture for rural development in Nigeria,” e-Prime – Advances in Electrical Engineering, Electronics and Energy, vol. 7, p. 100492, Mar. 2024, doi: 10.1016/j.prime.2024.100492.
  2. A. Shezan et al., “Effective dispatch strategies assortment according to the effect of the operation for an islanded hybrid microgrid,” Energy Conversion and Management: X, vol. 14, p. 100192, May 2022, doi: 10.1016/j.ecmx.2022.100192.
  3. O. Yakub, N. N. Same, A. B. Owolabi, B. E. K. Nsafon, D. Suh, and J. S. Huh, “Optimizing the performance of hybrid renewable energy systems to accelerate a sustainable energy transition in Nigeria: A case study of a rural healthcare centre in Kano,” Energy Strategy Reviews, vol. 43, Sep. 2022, doi: 10.1016/j.esr.2022.100906.
  4. Aziz, M. Tajuddin, M. Adzman, M. Ramli, and S. Mekhilef, “Energy Management and Optimization of a PV/Diesel/Battery Hybrid Energy System Using a Combined Dispatch Strategy,” Sustainability, vol. 11, no. 3, p. 683, Jan. 2019, doi: 10.3390/su11030683.
  5. Cano, P. Arévalo, and F. Jurado, “Energy analysis and techno-economic assessment of a hybrid PV/HKT/BAT system using biomass gasifier: Cuenca-Ecuador case study,” Energy, vol. 202, p. 117727, Jul. 2020, doi: 10.1016/j.energy.2020.117727.
  6. Ramesh and R. P. Saini, “Dispatch strategies based performance analysis of a hybrid renewable energy system for a remote rural area in India,” J Clean Prod, vol. 259, p. 120697, Jun. 2020, doi: 10.1016/j.jclepro.2020.120697.
  7. Amin Vaziri Rad, A. Shahsavari, F. Rajaee, A. Kasaeian, F. Pourfayaz, and W.-M. Yan, “Techno-economic assessment of a hybrid system for energy supply in the affected areas by natural disasters: A case study,” Energy Convers Manag, vol. 221, p. 113170, Oct. 2020, doi: 10.1016/j.enconman.2020.113170.
  8. Ramesh and R. P. Saini, “Demand Side Management based techno-economic performance analysis for a stand-alone hybrid renewable energy system of India,” Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, pp. 1–29, Jan. 2021, doi: 10.1080/15567036.2020.1851820.
  9. A. Shezan, S. S. Ali, and Z. Rahman, “Design and implementation of an islanded hybrid microgrid system for a large resort center for <scp>Penang Island</scp> with the proper application of excess energy,” Environ Prog Sustain Energy, vol. 40, no. 4, Jul. 2021, doi: 10.1002/ep.13584.
  10. Chen, H. Ren, and W. Zhou, “Review of multi-objective optimization in long-term energy system models,” Global Energy Interconnection, vol. 6, no. 5, pp. 645–660, Oct. 2023, doi: 10.1016/j.gloei.2023.10.010.
  11. I. Abba et al., “Emerging Harris Hawks Optimization based load demand forecasting and optimal sizing of stand-alone hybrid renewable energy systems– A case study of Kano and Abuja, Nigeria,” Results in Engineering, vol. 12, p. 100260, Dec. 2021, doi: 10.1016/j.rineng.2021.100260.
  12. Toopshekan, H. Yousefi, and F. R. Astaraei, “Technical, economic, and performance analysis of a hybrid energy system using a novel dispatch strategy,” Energy, vol. 213, p. 118850, Dec. 2020, doi: 10.1016/j.energy.2020.118850.
  13. Uwineza, H.-G. Kim, J. Kleissl, and C. K. Kim, “Technical Control and Optimal Dispatch Strategy for a Hybrid Energy System,” Energies (Basel), vol. 15, no. 8, p. 2744, Apr. 2022, doi: 10.3390/en15082744.
  14. Zhao et al., “Capacity optimization and energy dispatch strategy of hybrid energy storage system based on proton exchange membrane electrolyzer cell,” Energy Convers Manag, vol. 272, p. 116366, Nov. 2022, doi: 10.1016/j.enconman.2022.116366.
  15. F. Ishraque, Sk. A. Shezan, J. N. Nur, and Md. S. Islam, “Optimal Sizing and Assessment of an Islanded Photovoltaic <scp>‐Battery‐</scp> Diesel Generator Microgrid Applicable to a Remote School of Bangladesh,” Engineering Reports, vol. 3, no. 1, Jan. 2021, doi: 10.1002/eng2.12281.
  16. A. A. Yousef, R. Amjad, N. A. Alajmi, and H. Rezk, “Feasibility of integrated photovoltaic and mechanical storage systems for irrigation purposes in remote areas: Optimization, energy management, and multicriteria decision-making,” Case Studies in Thermal Engineering, vol. 38, p. 102363, Oct. 2022, doi: 10.1016/j.csite.2022.102363.
  17. B. Beyene, G. B. Worku, and L. B. Tjernberg, “On the design and optimization of distributed energy resources for sustainable grid-integrated microgrid in Ethiopia,” Int J Hydrogen Energy, vol. 48, no. 78, pp. 30282–30298, Sep. 2023, doi: 10.1016/j.ijhydene.2023.04.192.
  18. A. Adetoro, L. Olatomiwa, J. Tsado, and S. M. Dauda, “A comparative analysis of the performance of multiple meta-heuristic algorithms in sizing hybrid energy systems connected to an unreliable grid,” e-Prime – Advances in Electrical Engineering, Electronics and Energy, vol. 4, p. 100140, Jun. 2023, doi: 10.1016/j.prime.2023.100140.
  19. O. Oladigbolu, Y. A. Al-Turki, and L. Olatomiwa, “Comparative study and sensitivity analysis of a standalone hybrid energy system for electrification of rural healthcare facility in Nigeria,” Alexandria Engineering Journal, vol. 60, no. 6, pp. 5547–5565, Dec. 2021, doi: 10.1016/j.aej.2021.04.042.
  20. Jamshidi, K. Pourhossein, and M. Asadi, “Size estimation of wind/solar hybrid renewable energy systems without detailed wind and irradiation data: A feasibility study,” Energy Convers Manag, vol. 234, p. 113905, Apr. 2021, doi: 10.1016/j.enconman.2021.113905.
  21. A. El-Sattar, H. M. Sultan, S. Kamel, T. Khurshaid, and C. Rahmann, “Optimal design of stand-alone hybrid PV/wind/biomass/battery energy storage system in Abu-Monqar, Egypt,” J Energy Storage, vol. 44, p. 103336, Dec. 2021, doi: 10.1016/j.est.2021.103336.
  22. A. Adetoro, M. Ndubuka Nwohu, and L. Olatomiwa, “Techno-economic Analysis of Hybrid Energy System Connected to an Unreliable Grid: A Case Study of a Rural Community in Nigeria,” in 2022 IEEE Nigeria 4th International Conference on Disruptive Technologies for Sustainable Development (NIGERCON), IEEE, Apr. 2022, pp. 1–5. doi: 10.1109/NIGERCON54645.2022.9803128.
  23. Mohamed Ismail, H. K. Ng, S. Gan, and T. Lucchini, “Computational study of biodiesel–diesel fuel blends on emission characteristics for a light-duty diesel engine using Open FOAM,” Appl Energy, vol. 111, pp. 827–841, Nov. 2013, doi: 10.1016/j.apenergy.2013.05.068.

Article Statistics

Track views and downloads to measure the impact and reach of your article.

0

PDF Downloads

62 views

Metrics

PlumX

Altmetrics

GET OUR MONTHLY NEWSLETTER