Switching Reduction in a Symmetrical Cascaded Diode-Clamped Multilevel Inverter (SCDC MLI)
Authors
Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)
Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)
Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)
Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)
Faculty of Electrical Technology and Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka (Malaysia)
Article Information
DOI: 10.47772/IJRISS.2026.101100302
Subject Category: Social science
Volume/Issue: 10/11 | Page No: 4307-4317
Publication Timeline
Submitted: 2026-11-05
Accepted: 2026-11-10
Published: 2026-11-25
Abstract
Multilevel inverters (MLIs) are widely used in high-power applications because they offer lower harmonic distortion than conventional inverters. The three common MLI topologies are cascaded H-bridge, diode-clamped, and flying-capacitor inverters. However, conventional topologies require a large number of switching devices to achieve higher voltage levels, resulting in increased switching losses, hardware size, weight, cost, and control complexity. This project aims to simulate a symmetrical cascaded switching diode (SCSD) multilevel inverter topology, which uses fewer switching devices to reduce switching losses and simplify the circuit design. Single-phase and three-phase seven-level SCSD MLI topologies will be designed and simulated using MATLAB/Simulink. The simulation results will be analysed based on voltage total harmonic distortion (THDV) and current total harmonic distortion (THDI) under several of loads. Two switching techniques, namely triangular-wave switching and sinusoidal pulse-width modulation (SPWM), will be evaluated for both single-phase and three-phase configurations. The results show that the RL load produces the lowest (THDI) compared with the R and RC loads. For the single-phase configuration, the (THDI) values are 6.98% for triangular-wave switching and 5.82% for SPWM. For the three-phase configuration, the corresponding values are 0.89% and 0.88%, respectively. The (THDV) values for the four configurations are 25.47%, 47.90%, 11.91%, and 29.18%, respectively. Compared with conventional MLI topologies, which generally require more switching components, the proposed SCSD topology uses only seven switching devices to generate a seven-level output voltage. This reduction in the number of switching devices has the potential to reduce switching losses, hardware complexity, size, and cost.
Keywords
Multilevel Inverter, Symmetrical Cascaded Diode Claimed, Total Harmonic Distortion
Downloads
References
1. “Half bridge inverter: Circuit diagram, advantages, & its disadvantages,” ElProCus, 2020. [Google Scholar] [Crossref]
2. D. (Z. W.) Gao and K. Sun, “Full bridge inverter,” in Electric Renewable Energy Systems, 2016. [Google Scholar] [Crossref]
3. S. Naveensiva, “Multi-level inverter: A literature survey on topologies and control strategies,” Dept. Electr. Eng., KNIT, Sultanpur, India. [Google Scholar] [Crossref]
4. K. V. Kumar and R. S. Kumar, “Switching sequence control of reduced switch count multilevel inverter with multi carrier pulse width modulation,” International Journal of Scientific & Technology Research, vol. 8, no. 12, Dec. 2019. [Google Scholar] [Crossref]
5. H. Shahane, S. Onkarkar, P. Khandekar, Z. Bhagat, and R. Tondare, “Review of different PWM techniques,” International Journal of Engineering Research in Electrical and Electronic Engineering, vol. 4, no. 3, Mar. 2018. [Google Scholar] [Crossref]
6. S. Z. Nasir, “Introduction to multilevel inverters,” The Engineering Projects, Dec. 22, 2014. [Google Scholar] [Crossref]
7. M. Derakhshanfar, “Analysis of different topologies of multilevel inverters,” M.S. thesis, Dept. Energy Environ., Chalmers Univ. Technol., Gothenburg, Sweden, 2010. [Google Scholar] [Crossref]
8. A. M. Prasad, S. Thirumalaiah, U. Chaithanya, and P. Nagarjuna, “Simulation of new multilevel inverter topology,” International Journal of Emerging Trends in Electrical and Electronics, vol. 1, no. 1, pp. 68–73, 2013. [Google Scholar] [Crossref]
9. A. Nordvall, “Multilevel inverter topology survey,” 2011. [Google Scholar] [Crossref]
10. S. Z. Nasir, “Diode clamped multilevel inverters,” The Engineering Projects, 2014. [Google Scholar] [Crossref]
11. T. A. Meynard and H. Foch, “Multilevel conversion: High voltage choppers and voltage-source inverters,” in Proceedings of the IEEE Power Electronics Specialists Conference, 1992, pp. 397–403. [Google Scholar] [Crossref]
12. S. Khomfoi and L. M. Tolbert, “Multilevel power converters,” in Power Electronics Handbook, 2007, pp. 451–482. [Google Scholar] [Crossref]
13. M. R. Jannati Oskuee, E. Salary, and S. Najafi-Ravadanegh, “Creative design of symmetric multilevel converter to enhance the circuit’s performance,” IET Power Electronics, vol. 8, no. 1, pp. 96–102, 2015. [Google Scholar] [Crossref]
14. J. Adem, “Design and simulation of single-phase five-level symmetrical cascaded H-bridge multilevel inverter with reduced number of switches,” Dept. Electr. Electron. Eng., Univ. Agriculture, Makurdi, Nigeria. [Google Scholar] [Crossref]
15. IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, IEEE Std. 519-1992, 1993. [Google Scholar] [Crossref]
16. M. A. Sathik and K. Ramani, “A new symmetric cascaded multilevel inverter topology using single and double source unit,” Journal of Power Electronics, vol. 15, no. 4, pp. 951–963, 2015. [Google Scholar] [Crossref]
17. N. Mohan, T. M. Undeland, and W. P. Robbins, Power Electronics: Converters, Applications, and Design, 3rd ed. Hoboken, NJ, USA: Wiley, 2003. [Google Scholar] [Crossref]
18. K. V. Kumar and S. R. Kumar, “Advanced PWM techniques for control of power electronic converters in PV and motor drive systems,” International Journal of Pure and Applied Mathematics, vol. 118, pp. 1–21, 2018. [Google Scholar] [Crossref]
19. K. V. Kumar and S. R. Kumar, “Analysis of logic gates for generation of switching sequence in symmetric and asymmetric reduced switch multilevel inverter,” IEEE Access, vol. 7, pp. 97719–97731, 2019, doi: 10.1109/ACCESS.2019.2929836. [Google Scholar] [Crossref]
20. K. V. Kumar and S. R. Kumar, “Switching sequence control of reduced switch count multilevel inverter with multi carrier pulse width modulation,” International Journal of Scientific & Technology Research, vol. 8, pp. 3790–3798, 2019. [Google Scholar] [Crossref]
Metrics
Views & Downloads
Similar Articles
- The Impact of Ownership Structure on Dividend Payout Policy of Listed Plantation Companies in Sri Lanka
- Urban Sustainability in North-East India: A Study through the lens of NER-SDG index
- Performance Assessment of Predictive Forecasting Techniques for Enhancing Hospital Supply Chain Efficiency in Healthcare Logistics
- The Fractured Self in Julian Barnes' Postmodern Fiction: Identity Crisis and Deflation in Metroland and the Sense of an Ending
- Impact of Flood on the Employment, Labour Productivity and Migration of Agricultural Labour in North Bihar