Analysis of the Academic Performance of the Students of Tertiary Level on Consumption of Excess CO2: A Case Study on Advanced Technological Institute of Batticaloa.
- Mr. K. Thevaruban
- 1072-1085
- Sep 11, 2025
- Information Technology
Analysis of the Academic Performance of the Students of Tertiary Level on Consumption of Excess CO2: A Case Study on Advanced Technological Institute of Batticaloa.
Mr. K. Thevaruban
Assistant Lecturer in Information Technology Sri Lanka Institute of Advanced Technological Education
DOI: https://dx.doi.org/10.47772/IJRISS.2025.915EC00732
Received: 04 August 2025; Accepted: 11 August 2025; Published: 11 September 2025
ABSTRACT
Clean breathing plays a huge role in our healthy well-being. When we inhale polluted air, it causes numerous unhealthy conditions for people. Indoor air is polluted by several factors, in which carbon dioxide (CO₂) plays a huge role. CO₂ and bio-effluents are natural products of human metabolism, but high CO₂ levels can result in unhealthy symptoms such as sore throat, irritated nose/sinus, combined mucous membranes, tight chest, wheezing, and low performance in academic activities. In a closed room where most people sleep (especially middle- and poor-class families) on the floor without using a bed, there is a high possibility of inhaling a high amount of CO₂. Ventilation is important to expel indoor-generated pollutants from indoor air or reduce their concentration to satisfactory levels. But ventilation and excess CO₂ are significant challenges to those who are middle-class and poor. The purpose of this study is to suggest a bearable ventilation solution to the students who are suffering from respiratory diseases due to excessive CO₂ and help them achieve good academic performance.
For this research study, a stratified sampling method is used to analyze the collected data. Advanced Technological Institute (ATI) Batticaloa, functioning under the Sri Lanka Advanced Technological Institute (SLIATE), is the geographical boundary for this research study. The population for this study includes the students who had low academic performance in the Advanced Technological Institute (ATI) Batticaloa. Initially, the simple random sampling method is applied for selecting 100 samples from the proposed population using secondary data (results published by the Exam Department-SLIATE). Then, 30 samples were selected among 100 samples for our study based on the following criteria using a closed questionnaire: Students should have pulmonary disease; families in which more than three occupants are sleeping together; the bedrooms of their families have very little or no ventilation. Thereafter, an automated ventilation system was fixed inside their bedrooms. The academic performance of the same students was re-examined after ensuring that their health was properly maintained. The analysis of exam results indicated an overall improvement in students’ post-test GPA (Grade Point Average) compared to their pre-test GPA, with varying degrees of improvement among individual students. Statistical analysis using the paired t-test confirmed a statistically significant mean difference in GPA, supporting the hypothesis that the Purifying indoor air polluted by excess CO₂ does have a positive effect on students’ academic performance. The study concludes that the purification of indoor air polluted by excess CO₂ has a positive impact on students’ academic performance. By reducing CO₂ concentration and improving indoor air quality, students’ focus, activeness, and overall academic performance can be enhanced. The study highlights the significance of affordable and accessible ventilation solutions in creating healthier and more conducive learning environments.
Keywords: Indoor air quality, Carbon dioxide (CO₂), Academic performance, Automated ventilation system, IoT-based ventilation, Tertiary education, Sri Lanka, Respiratory health
INTRODUCTION
Background of the study
Clean air is essential for maintaining health and well-being. The World Health Organization (WHO) notes that breathing clean air reduces the risk of stroke, heart disease, lung cancer, and respiratory diseases. However, 99% of the global population breathes contaminated air, making air pollution one of the most significant threats to human health. Indoor air pollution is associated with respiratory infections—particularly among children, the elderly, and women—as well as allergies and building dampness issues (Gautier & Charpin, 2017). Carbon dioxide (CO₂), which is approximately 1.67 times denser than air, tends to remain near the bottom of enclosed spaces (Kurtzman, 2010). A study by Tian et al. (2023) reported that indoor air quality declines significantly when CO₂ exceeds recommended levels and suggested incorporating CO₂ purification modules into existing air conditioning systems to maintain healthy concentrations. Ventilation is essential for reducing indoor contaminants to acceptable levels. Modern air conditioning systems can effectively filter indoor air; however, such solutions are often affordable only to high-income households. Middle- and low-income families face greater challenges in addressing ventilation and CO₂ buildup. While opening windows and doors can help, this is not always practical—particularly at night—due to issues such as mosquito infestations and outdoor dust from construction sites. Academic performance is closely linked to health and cognitive function. Students with higher academic achievement often gain better employment prospects, higher salaries, and greater self-confidence. Exam performance serves as an important indicator of educational program effectiveness. Consequently, researchers have sought to identify environmental and personal factors that influence academic outcomes. Kabirikopaei et al. (2021) demonstrated a strong association between indoor air quality factors—such as ventilation system type, ventilation rates, fine particle counts, and O₃ and CO concentrations—and student scores. Similarly, Gardin and Requia (2023), in a nationwide Brazilian study, found that air pollution exposure was associated with declines in student marks ranging from 0.13% to 5.39%. Preliminary observations at ATI Batticaloa suggested that some students with poor academic performance also experienced respiratory symptoms, possibly linked to poor indoor air quality and excessive CO₂ exposure. These observations align with prior findings that reduced activity levels and diminished concentration may result from prolonged exposure to polluted indoor air. Based on this evidence, the present study investigates the impact of inhaling indoor air polluted by excess CO₂ on students’ academic performance at ATI Batticaloa and proposes an affordable ventilation solution suitable for middle- and low-income households.
“What is the effect of inhaling indoor air polluted by excess CO2 on students’ academic performance?”
Justification
In recent years, several studies have focused on excessive CO₂ levels and unhealthy symptoms, especially respiratory diseases such as sore throat, irritated nose/sinus, combined mucous membrane, tight chest, and wheezing. This research study evaluates the effect of inhaling indoor air polluted by excess CO₂ on students’ academic performance. Multiple studies (Alsubaie, 2014; Hedrick et al., 2013; Seppänen & Fisk, 2004; Sundell et al., 2011; Taylor et al., 2016) have examined the relationship between respiratory disease, CO₂ concentration, and ventilation. In general, these examinations provide evidence that there is a concrete connection between ventilation and respiratory disease. A study (Stafford, 2015) was conducted to investigate the effect of indoor air quality (IAQ) in school buildings on students’ standardized test scores and school attendance rates. Several studies have been carried out on high CO₂ levels and respiratory disorders in different countries. Furthermore, several studies have been focused on the relationship between indoor air quality and students’ academic performance.
However, there is limited empirical evidence on the effect of inhaling CO₂-polluted indoor air on academic performance in the Sri Lankan tertiary education context. This gap in the literature is particularly relevant for institutions serving middle- and low-income communities, where poor ventilation is more prevalent.
This study addresses that gap by investigating the impact of excessive indoor CO₂ exposure on the academic performance of students at the Advanced Technological Institute (ATI), Batticaloa. It also aims to quantify the relationship between CO₂ concentration and academic outcomes and to evaluate the effectiveness of an Internet of Things (IoT)-based automated ventilation system in maintaining healthy indoor air quality. By doing so, the research offers practical, low-cost interventions that could be applied in similar low-resource educational settings.
Research Objectives
The main objective of this study is to “examine the impact of inhaling indoor air polluted by excess CO₂ on the academic performance of students at the Advanced Technological Institute (ATI) Batticaloa.”.
To accomplish the main objective, the specific objectives are identified as follows.
- To identify the students who are affected by respiratory diseases among the students who possess poor academic performance.
- To Measure the concentration of CO₂ in the bedrooms of selected students.
- To propose and implement IOT (Internet Of Things) based Automated ventilation system to maintain their health properly.
- To evaluate whether the students’ academic performance has increased or not after integrating the proposed system.
REVIEW OF LITERATURE
Multiple studies (Guo et al., 2023; Doutreleau et al., 2017; Zhang et al., 2017; Bekö et al., 2010; Corradi & Mutti, 2005) have focused on excessive CO2 levels and harmful symptoms, particularly respiratory illnesses. Guo et al. (2023) assessed the effects of indoor Negative air ions(NAIs) on college students’ cognitive performance, including reasoning, short-term memory, concentration, verbal ability, and health when they are exposed to high levels of pure CO2. Four distinct scenarios (NAIs+500 ppm CO2, 500 ppm CO2, NAIs+2500 ppm CO2, and 2500 ppm CO2) were presented to forty college students. A subjective questionnaire was used to examine acute health symptoms, and the participants’ lung function, heart rate, and blood pressure were all measured at the same time. The findings show that adding NAIs can lessen the symptoms of pure CO2-induced heart rate rise, nose irritation or dryness, skin irritation or dryness, and sensations of tiredness. So, this study clearly shows that a high pure CO2 level causes unhealthy symptoms.
Zhang et al (2017) examined how exposure to bio effluents and carbon dioxide (CO2) affects people. The reference condition was modified with chemically pure CO2 to produce exposure conditions with CO2 at 1000 ppm or 3000 ppm. The same 25 participants were subjected to each condition for 255 minutes. Measurements were made on subjective evaluations, physiological reactions, and mental performance. The results revealed that exposures to bio effluents with CO2 at 3000 ppm reduced perceived air quality; increased the intensity of reported headache, fatigue, sleepiness, and difficulty in thinking clearly; and reduced the speed of addition, the response time in a redirection task, and the number of correct links made in the cue-utilization test compared to pure CO2.
Tsai et al. (2012) carried out a study in Taiwan to determine whether any association exists between sick building syndrome (SBS) and indoor carbon dioxide (CO2) concentrations. 111 office workers were subjected to this study, and the results showed that workers exposed to indoor CO2 levels greater than 800 ppm were likely to report more eye irritation or upper respiratory symptoms. A significant study (Shriram et al., 2019) found that sick building syndrome (SBS) symptoms and poor perceived air quality were both caused by ventilation rates of less than 10 L/sec per person. And they demonstrated that exposure to CO2 concentrations greater than 1000 ppm resulted in reduced school attendance as well as more severe headaches, fatigue, and concentration problems. Ventilation is the only way to purify the polluted indoor air rather than using modern air-conditioner and specialized electrical equipment when we considering the economy of the people, Several studies (Alsubaie, 2014; Hedrick et al., 2013; Seppänen & Fisk, 2004; Sundell et al., 2011; Taylor et al., 2016) examined at the association between respiratory disease, CO2 concentration, and ventilation. A study (Lee et al., 2014) examined the association between indoor air pollutant levels and residential environment in children with atopic dermatitis (AD) living in Seoul. One of the most prevalent allergic illnesses in children is atopic dermatitis (AD), a persistent, itchy, and inflammatory skin condition. Pet hair, house dust mites, pollen, and breathing contaminated air are the main causes of the condition. They included 150 AD patients from Seoul in the trial. A questionnaire was used to evaluate the living environment, and indoor air pollution levels were directly measured within the homes. From this study, they proved that CO and CO2 play a major role in ways that cause Atopic Dermatitis in humans.
López et al. (2023) carried out the study on Indoor Air Pollutants (IAPs). They mentioned that CO2 is the most common IAP among them and is commonly used as a metric of IAQ. Indoor CO2 concentrations can be significantly higher than outdoors due to human metabolism and activities, and they suggested that direct air capture technology can purify indoor air by reducing the CO2 concentration.
Tian et al., (2023) built a CO2 purification module that can be incorporated with existing air conditioning systems to maintain the indoor CO2 concentration at healthy levels and they proved that their CO2 purification module can keep the indoor CO2 level to be close to or even lower than outdoor levels with an initial CO2 concentration of 1000 or 2000 ppm. Stafford (2015) carried out the study in Texas to examine the effect of school indoor air quality (IAQ) on academic outcomes. The results showed that the indoor air quality renovations have a significant effect on academic outcomes, with performance on standardized tests improving significantly while attendance is unresponsive. Rough calculations suggest that indoor air quality renovations may be more cost-effective than class size reductions to improve test scores.
A large-scale study (Kabirikopaei et al., 2021) examined the associations between indoor air quality factors and student performance in K-12 classrooms in the Midwestern US. Various IAQ parameters were assessed seasonally in 220 US classrooms from the academic years 2015 to 2017, excluding the summer. The findings revealed that classroom indoor air quality is significantly influenced by mechanical system types and sufficient ventilation rates, and that these parameters have a significant impact on student learning outcomes. In addition, they suggested that adequate ventilation rates and efficient filters help to dilute contaminants in classrooms and potentially improve the performance of the students.
A study (Haverinen-Shaughnessy et al., 2015) was conducted in a 70-school district in the Southwestern United States during two academic years in order to examine the associations between different indoor environmental quality (IEQ) indicators and students’ performance. The temperature (T), relative humidity (RH), carbon dioxide (CO2), and settled dust were all measured. Significant correlations were found between the percentage of students passing math and reading exams and both indoor temperature (r =-.353 and r=-.311 respectively) and ventilation rate (r =.417 and r=.479 respectively), which were measured using CO2 levels. The results have shown that the rate and temperature of the classroom ventilation, as well as the cleanliness of the high-touch surfaces, seem to be significant IEQ variables that could potentially be related to students’ health or academic performance. The findings support the generalization that surface cleaning, heating, ventilation, and air conditioning are the key operational measures for modifying the school environment to enhance students’ health and academic performance.
According to the studies mentioned above, excess CO2 is one of the main contaminants polluting indoor air, and indoor air can be purified by removing excess CO2 using a CO2 purification module that can be incorporated into existing ventilation systems. The above-mentioned studies (Stafford, 2015; Kabirikopaei et al., 2021; Haverinen-Shaughnessy et al., 2015) show the concrete association between indoor air quality and students’ academic performance.
Thus, this study intended to focus on the application of the concepts in the Sri Lankan context, as there is limited research that has been conducted in this area of study in Sri Lanka as well as other developing countries.
METHODOLOGY
Research Design
This study adopted a quantitative panel design to evaluate changes in academic performance among students with previously poor results who also suffered from respiratory diseases. Statistical data were used to assess the impact of improved indoor air quality following the installation of an automated ventilation system in their bedrooms. Academic performance was measured both before and after the intervention.
Research Hypothesis
This present study focuses on the impact of indoor air polluted by excessive CO2 levels on students’ academic performance.
H₁ (Alternative Hypothesis):
Purifying indoor air polluted by excess CO₂ does have a positive effect on students’ academic performance.
H₀ (Null Hypothesis):
Purifying indoor air polluted by excess CO₂ does not affect students’ academic performance.
Structure of the Questionnaire
The questionnaire contained two sections:
- Personal information – age, gender, number of family members, number of bedrooms.
- Research-related information – number of occupants per bedroom, average sleeping duration, ventilation availability, and presence of pulmonary patients in the household.
Closed-ended questions were used to ensure efficiency and reliability when collecting responses from groups of students.
Study Population and Sampling
The study was conducted at the Advanced Technological Institute (ATI), Batticaloa. The target population comprised students with a Grade Point Average (GPA) below 2.0, as defined in the SLIATE Student Handbook (2017 onwards). Using secondary data from the Examination Department, 100 students were initially selected through simple random sampling. From this group, 30 students were chosen using stratified sampling based on the following criteria:
- The student had a diagnosed pulmonary disease.
- The student’s family included more than three occupants sleeping in the same bedroom.
- The bedroom had very little or no ventilation.
The final sample included 15 students from the Higher National Diploma in Information Technology (HNDIT), 7 from Higher National Diploma in English (HNDE), 6 from Higher National Diploma in Accountancy (HNDA), and 2 from Higher National Diploma in Tourism and Hospitality Management (HNDTHM).
Table 1. Distribution of Students with Low Academic Performance by Department and GPA
No | Student Name | Department | GPA |
1 | S1 | HNDIT | 0.78 |
2 | S2 | HNDIT | 1.51 |
3 | S3 | HNDIT | 0.83 |
4 | S4 | HNDIT | 1.7 |
5 | S5 | HNDIT | 0.82 |
6 | S6 | HNDIT | 0.45 |
7 | S7 | HNDIT | 0.41 |
8 | S8 | HNDIT | 1.47 |
9 | S9 | HNDIT | 0.99 |
10 | S10 | HNDIT | 0.6 |
11 | S11 | HNDIT | 1.7 |
12 | S12 | HNDIT | 1.17 |
13 | S13 | HNDIT | 1.84 |
14 | S14 | HNDIT | 1 |
15 | S15 | HNDIT | 0.97 |
16 | S16 | HNDE | 1.5 |
17 | S17 | HNDE | 1.26 |
18 | S18 | HNDE | 1.59 |
19 | S19 | HNDE | 1.29 |
20 | S20 | HNDE | 1.98 |
21 | S21 | HNDE | 1.82 |
22 | S22 | HNDE | 1.05 |
23 | S23 | HNDA | 1.19 |
24 | S24 | HNDA | 1.88 |
25 | S25 | HNDA | 0.56 |
26 | S26 | HNDA | 1.7 |
27 | S27 | HNDA | 1.41 |
28 | S28 | HNDA | 1.88 |
29 | S29 | HNDTHM | 1.41 |
30 | S30 | HNDTHM | 1.76 |
Then, data was gathered twice from 30 students selected for our study and evaluated for the recommended solution. The selected 30 students were informed in detail about our study and the benefits of the study to them. As well, an acceptance letter was given to each student to continue the study (because we needed to deploy our developed system in their bedrooms).
The selected 30 students’ bedroom conditions needed to be studied, such as CO₂ concentration while they sleep, the ventilation rate in their bedrooms, the amount of CO₂ produced by their metabolic process, and the rate of change of CO₂ concentration with time. Sleeping time, the number of occupants who are sleeping in a bedroom, and ventilation details were recorded from earlier data collection via questionnaire. The CO₂ concentration and the rate of change of the CO₂ concentration with time are the only additional requirements. The CO₂ concentration reader was developed to collect those details, and it was deployed in the 30-bed rooms.
A study (Pirapuraj et al., 2021) examined the indoor CO2 concentration, and they suggested an automated ventilation system for maintaining the indoor CO2. They developed a CO2 concentration reader using a Raspberry Pi, a CO2 sensor, and a power supply. The Raspberry Pi had been selected to develop the CO2 concentration reader rather than using Arduino, because when Arduino is used, getting a timestamp is difficult. The timestamp was needed to analyze how the CO2 concentration is changing with time. It was easy to use the Raspberry Pi because the Raspberry Pi has an operating system (a Linux operating system) in it. Therefore, getting system time from the operating system is easy. And a Memory Chip (Memory SD Card) in it to store the record frequently. The same system was developed for this study.
RESULTS ANALYSIS AND DISCUSSION
Analysis of data collected from 30 students
Figure 1: Full CO2 concentration reading of the bedroom of 30 students (9:30:00 PM to 6:30:00PM) every 01 minute
As discussed in Section 5, the CO₂ concentration and its rate of change over time were measured in the bedrooms of selected students. Figure 1 illustrates how the CO₂ concentration changes over time in the bedrooms of 30 students. Measurements were taken between 9:30 PM and 6:30 AM. The indoor air quality in the bedrooms of students S1, S8, and S24 was in a highly critical condition, with CO₂ concentrations exceeding 3000 PPM. The bedrooms of other students, except for S3, S7, S10, S13, S14, and S25, were also in unhealthy conditions, with concentrations above 1000 PPM. Students S3, S7, S10, S13, S14, and S25 slept in healthy environments, inhaling fresh air with an average CO₂ level of about 500 PPM. They did not require any ventilation devices as their bedrooms already had good ventilation. Therefore, students S3, S10, S13, S14, and S25 were excluded from further research analysis.
The remaining 24 students were selected for the deployment of the developed system-an automated ventilation system.
Analysis of data collected using an automated ventilation system
Prapuraj et al. (2021) developed an automated ventilation system that maintains the indoor CO2 concentration below 1000 PPM. They set the maximum CO2 concentration value at 1000 PPM and the minimum CO2 concentration value at 500 PPM in their developed system. The CO2 sensor of the system monitors the CO2 concentration inside the bedrooms. Once the maximum threshold value is reached, it reduces the CO2 concentration by switching on the exhaust fan, and it will continue to work until the minimum threshold value is reached. Likewise, the CO2 concentration inside the bedroom is maintained in a healthy range.
Figure 2. CO₂ concentration in bedrooms with automated ventilation, maintained between 500–1,000 ppm.
Initially, four students were selected to validate the system, and automatic ventilation was deployed in their bedrooms. Figure 2 describes how the CO2 concentration changes over time in the bedrooms of selected students after the deployment of the automated ventilation system.
When we see Figure 2, the maximum CO2 concentration value is 1000 PPM, and the minimum CO2 concentration value is 500 PPM inside all the bedrooms of the four selected students. It means the CO2 sensor monitors the CO2 concentration inside the bedrooms; once the maximum threshold value is reached, it reduces the CO2 concentration via the switch on the exhaust, and it will continue to work until the minimum threshold value is reached. Likewise, the CO2 concentration inside the bedroom is maintained in a healthy range. So, the automated ventilation system maintains the indoor health condition perfectly. Finally, the developed system was deployed in the remaining 20 bedrooms of the students. The developed system was kept in all selected students’ bedrooms for an entire semester. The examination results of the chosen research participants were considered for further studies.
Analysis of exam results after the deployment of the system
Figure 3. Pre-test and post-test GPA for 24 students after automated ventilation intervention.
Figure 3 describes the comparative analysis of the post-test GPA and pre-test GPA differences on student academic performance. Here are a few observations based on the above figure:
Overall Improvement: A majority of the students demonstrated an increase in their post-test GPA compared to their pre-test GPA. This suggests an overall improvement in academic performance.
Varying Magnitude of Improvement: The extent of improvement varied among the students. Some students exhibited significant improvements, such as S4 (0.45 increase), S16 (0.50 increase), and S28 (0.61 increase). On the other hand, some students showed smaller improvements, like S1 (0.22 increase), S9 (0.19 increase), and S11 (0.24 increase).
Stable Performance: Several students maintained a relatively consistent GPA between the pre-test and post-test, with minimal differences. Examples include S5 (0.03 increase), S15 (-0.02 decrease), and S22 (-0.05 decrease).
Minor Declines: Few students experienced a slight decrease in their post-test GPA compared to their pre-test GPA. Notable examples are S8 (-0.05 decrease), S17 (-0.06 decrease), and S18 (-0.09 decrease).
The findings indicate that a substantial number of students experienced a positive GPA difference, suggesting academic progress and an improvement in their learning outcomes after the deployment of the automated ventilation system. Further statistical analysis was performed on the above findings to support the research hypothesis. Statistical verification of these differences was conducted using a paired-samples t-test in SPSS (Version 23), as reported in Tables 2 and 3.
Analysis of the statistical test
The paired t-test is used to compare the difference between two means of related samples. Related samples indicate measurements taken from the same subjects at two or more different times/situations. Table 2 shows Descriptive statistics for pre-test and post-test GPA scores of participating students.
Table 2. Descriptive statistics for pre-test and post-test GPA scores of participating students.
Table 3. Paired samples t-test results comparing pre-test and post-test GPA scores.
This research study investigated the impact of purifying indoor air polluted by excess CO₂ on students’ academic performance. The paired sample test results revealed a statistically significant mean difference in GPA between the post-test and pre-test measurements. The findings suggest that purifying indoor air polluted by excess CO₂ positively affects students’ academic performance.
The mean difference of 0.15875 indicates an average increase in GPA following the purification process. This suggests that improving indoor air quality through purification measures can contribute to enhanced academic outcomes for students. The 95% confidence interval (0.04735 to 0.27015) further supports these findings, indicating a high level of confidence that the true population mean difference falls within this range.
The statistical analysis, with a t-value of 2.948 and a corresponding p-value of 0.007, demonstrates the statistical significance of the observed mean difference. This indicates that the likelihood of obtaining such a significant difference by chance alone is relatively low. Consequently, the null hypothesis—that purifying indoor air polluted by excess CO₂ does not affect students’ academic performance—can be rejected.
These results align with previous research highlighting the importance of indoor air quality in educational settings. For example, Stafford (2015) examined the effect of indoor air quality (IAQ) renovations in schools on academic outcomes and found that improvements in IAQ had a significant positive impact on standardized test scores, indicating that students’ performance improves as a result of IAQ enhancements.
Similarly, Kabirikopaei et al. (2021) examined the associations between IAQ in K–12 classrooms and student academic performance. A multivariate linear regression analysis was conducted to investigate the relationships between IAQ factors and student scores while controlling for demographic variables. The results revealed significant associations between student scores and factors such as ventilation system type, ventilation rates (estimated from measured CO₂ concentrations), fine particle counts, and O₃ and CO concentrations. The findings highlight the importance of considering IAQ factors—such as ventilation rates and pollutant concentrations—in educational settings to create healthier and more conducive learning environments.
Haverinen-Shaughnessy et al. (2015) also assessed indoor environmental quality (IEQ) in schools and its association with health and performance. This study found significant relationships between IEQ indicators and student performance. Specifically, indoor temperature and ventilation rate were correlated with students’ satisfactory scores in mathematics and reading tests.
High levels of CO₂ in indoor environments have been associated with adverse health effects and reduced cognitive performance. The current study provides further evidence supporting the positive impact of air purification measures in mitigating these effects and improving students’ academic performance.
While the observed GPA improvements were associated with reduced indoor CO₂ levels, it is important to note that other factors may have contributed to the results. For example, students’ socioeconomic background could influence access to better nutrition, healthcare, and study resources, which in turn affect academic outcomes. Environmental stressors such as noise pollution, humidity, or poor lighting may also impact concentration and performance. Additionally, differences in individual study habits, family support, and extracurricular commitments could have played a role. Although these confounding variables were not controlled for in the present study, acknowledging them is essential for interpreting the findings with appropriate caution. Future research should incorporate these variables into the study design to better isolate the specific effects of CO₂ reduction on academic performance.
CONCLUSION, RECOMMENDATIONS, AND LIMITATIONS
Conclusion
This research study investigated the impact of inhaling indoor air polluted by excess CO₂ on students’ academic performance and explored the effectiveness of a purification system in improving indoor air quality. The findings of the study indicate that the purification of indoor air polluted by excess CO₂ has a positive effect on students’ academic performance.
The analysis of exam results revealed an overall improvement in students’ post-test GPAs compared to their pre-test GPAs. While the magnitude of improvement varied among students, a substantial number demonstrated positive GPA differences, indicating academic progress and enhanced learning outcomes. Statistical analysis using the paired t-test confirmed the significance of the observed mean difference, supporting the research hypothesis that purification measures positively influence students’ academic performance.
These findings align with previous research studies highlighting the importance of indoor air quality in educational settings. Other studies have shown that improvements in indoor air quality have a significant positive impact on standardized test scores and student performance. Factors such as ventilation rates, pollutant concentrations, and IAQ indicators have been linked to students’ academic achievements, emphasizing the need to consider IAQ factors in creating healthier and more conducive learning environments.
The current study contributes to the existing body of knowledge by providing evidence of the positive impact of air purification measures in mitigating the adverse effects of indoor air pollution on students’ academic performance. By reducing excess CO₂ and improving indoor air quality, students’ focus, activeness, and overall academic performance can be enhanced. This research highlights the importance of affordable and accessible ventilation solutions, particularly for middle-class and low-income families who may face challenges in dealing with indoor air pollution.
In conclusion, the implications of this study are significant, as they underscore the need for effective air purification systems to create a healthier and more conducive learning environment. By improving indoor air quality through the reduction of CO₂ pollution, educational institutions can enhance academic outcomes for students.
It is important to acknowledge potential limitations of the study, such as the specific context and sample characteristics. Further research is recommended to validate and generalize these findings across diverse educational settings and student populations. Additionally, exploring the underlying mechanisms driving the observed improvements in academic performance would provide valuable insights for future interventions and policies aimed at enhancing indoor air quality and optimizing learning environments.
RECOMMENDATIONS
Based on the conclusion of the research study, the following recommendations can be made:
- Implement Effective Air Purification Systems: Educational institutions should prioritize the installation and maintenance of air purification systems to improve indoor air quality. These systems should specifically target the reduction of CO2 pollution, as it has been shown to have a positive impact on students’ academic performance. Regular monitoring and maintenance of these systems are essential to ensure their effectiveness.
- Raise Awareness and Provide Education: Schools, teachers, and parents should be educated about the importance of indoor air quality and its impact on students’ academic performance. Workshops, training sessions, and information campaigns can help raise awareness about the benefits of clean indoor air and the role of air purification systems. This knowledge can empower stakeholders to take necessary actions to create healthier learning environments.
- Consider Ventilation Solutions: Along with air purification systems, effective ventilation solutions should be implemented in the bedrooms of students and educational settings. Adequate ventilation helps in maintaining good indoor air quality by promoting the circulation of fresh air and the removal of pollutants.
- Encourage Collaboration and Research: Collaboration between educational institutions, researchers, and policymakers is essential to further investigate the relationship between indoor air quality and academic performance. Future research should focus on diverse educational settings and student populations to validate the findings and generalize the outcomes. Additionally, studying the underlying mechanisms and specific factors influencing the observed improvements in academic performance can guide the development of targeted interventions.
- Provide Support for Low-Income Families: Special attention should be given to middle-class and low-income families who may face challenges in dealing with indoor air pollution. Affordable and accessible air purification systems, along with educational resources on maintaining good indoor air quality, should be made available to these families. Policies and initiatives should aim to reduce indoor air pollution disparities and ensure that all students have access to a healthy learning environment.
Limitations
While the research study provides valuable insights into the impact of indoor air pollution on academic performance and the effectiveness of ventilation solutions, it is important to consider its limitations. Here are some limitations of the research:
- Sample Size and Selection: The study relies on a relatively small sample size of 30 students from a single institution. The generalizability of the findings to a larger population may be limited. The use of judgment sampling further restricts the representativeness of the sample.
- External Factors: The research does not account for other potential factors that could influence academic performance, such as socioeconomic status, sleep quality, study habits, or other environmental factors outside of CO2 These factors may confound the relationship between indoor air quality and academic performance.
- Subjective Measurement: The academic performance of the students is assessed based on GPA, which may not capture the complete picture of their abilities and achievements. Other objective measures or performance assessments could provide a more comprehensive evaluation.
- Lack of Long-term Follow-up: The research study does not provide information on the long-term effects of improved indoor air quality on academic performance. It would be valuable to track the students’ progress over an extended period to assess the sustainability of the intervention’s impact.
- Potential confounding variables: Socioeconomic status, noise levels, lighting conditions, and students’ study habits were not measured or controlled for in this study. These factors may have contributed to changes in academic performance and should be considered in future research.
ACKNOWLEDGMENTS
The author would like to thank all of those who participated in our experiments. Special gratitude goes to the students of ATI Batticaloa who helped to get data from their families.
REFERENCES
- Alsubaie, A. S. R. (2014). Indoor Air Ventilation in Primary Schools in Eastern Province , Saudi Arabia. International Journal of Current Research, 6(5), 6552–6557.
- Ang, I. B. A., Dilys Salim, F., & Hamilton, M. (2016). Human occupancy recognition with multivariate ambient sensors. 2016 IEEE International Conference on Pervasive Computing and Communication Workshops, PerCom Workshops 2016. https://doi.org/10.1109/PERCOMW.2016.7457116
- Apte, M. G. (2000). Associations between indoor CO2 concentrations and sick building syndrome symptoms in U.S. office buildings: An analysis of the 1994-1996 BASE study data. Indoor Air, 10(4), 246–257. https://doi.org/10.1034/j.1600-0668.2000.010004246.x
- Arief-Ang, I. B., Hamilton, M., & Salim, F. D. (2018a). A scalable room occupancy prediction with transferable time series decomposition of CO2 sensor data. ACM Transactions on Sensor Networks, 14(3–4). https://doi.org/10.1145/3217214
- Arief-Ang, I. B., Hamilton, M., & Salim, F. D. (2018b). RUP: Large Room Utilisation Prediction with carbon dioxide sensor. Pervasive and Mobile Computing, 46, 49–72. https://doi.org/10.1016/j.pmcj.2018.03.001
- Basu, C., Koehler, C., Das, K., & Dey, A. K. (2015). PerCCS: Person-count from carbon dioxide using sparse non-negative matrix factorization. UbiComp 2015 – Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing, 987–998. https://doi.org/10.1145/2750858.2807525
- Bekö, G., Lund, T., Nors, F., Toftum, J., & Clausen, G. (2010). Ventilation rates in the bedrooms of 500 Danish children. Building and Environment, 45(10), 2289–2295. https://doi.org/10.1016/j.buildenv.2010.04.014
- Billionnet, C., Gay, E., Kirchner, S., Leynaert, B., & Annesi-Maesano, I. (2011). Quantitative assessments of indoor air pollution and respiratory health in a population-based sample of French dwellings. Environmental Research, 111(3), 425–434. https://doi.org/10.1016/j.envres.2011.02.008
- Caddick, Z. A., Gregory, K., Arsintescu, L., & Flynn-Evans, E. E. (2018). A review of the environmental parameters necessary for an optimal sleep environment. Building and Environment, 132, 11–20. https://doi.org/10.1016/j.buildenv.2018.01.020
- Chronic respiratory diseases. (n.d.). Retrieved April 23, 2020, from https://www.who.int/health-topics/chronic-respiratory-diseases#tab=tab_1
- Corradi, M., & Mutti, A. (2005). Exhaled breath analysis: From occupational to respiratory medicine. Acta Biomedica de l’Ateneo Parmense, 76(SUPPL. 2), 20–29.
- Doutreleau, S., Enache, I., Pistea, C., Favret, F., Lonsdorfer, E., Dufour, S., & Charloux, A. (2017). Cardio-respiratory responses to hypoxia combined with CO2 inhalation during maximal exercise. Respiratory Physiology and Neurobiology, 235, 52–61. https://doi.org/10.1016/j.resp.2016.09.012
- Ejaimi, G., & Saeed, S. (2016). An Introduction to Airway Assessment and Management (Concise Airway Anatomy and Pathophysiology). Annals of International Medical and Dental Research, 3(1), 1–7. https://doi.org/10.21276/aimdr.2017.3.1.an1
- Gautier, C., & Charpin, D. (2017). Environmental triggers and avoidance in the management of asthma. 47–56.
- Gids de, F. W., & Wouters, P. (2010). CO2 as indicator for the indoor air quality. General principles. Ventilation Information Paper, AIVC, 33, 4. http://www.aivc.org/sites/default/files/members_area/medias/pdf/VIP/VIP 33_CO2pdf
- Guo, M., Yu, W., Sun, Y., Wang, L., Zhou, H., & Zhang, Y. (2023). Effects of Increasing Indoor Negative Air Ions on Cognitive Performance and Health of High Pure CO2 Level-Exposed College Students. Indoor Air, 2023, 1–11. https://doi.org/10.1155/2023/8298339
- Haverinen-Shaughnessy, U., Shaughnessy, R. J., Cole, E. C., Toyinbo, O., & Moschandreas, D. J. (2015). An assessment of indoor environmental quality in schools and its association with health and performance. Building and Environment, 93(P1), 35–40. https://doi.org/10.1016/j.buildenv.2015.03.006
- Hedrick, R. L., Thomann, W. R., Aguilar, H., Damiano, L. A., Darwich, A. K. H., Gress, G., Habibi, H., Howard, E. P., Petrillo-groh, L. G., Smith, J. K., Williams, S. D., Doppel, P. L., Davis, H. D., Fisher, F. J., Morris, W. E., Olsen, J. W. W., Hall, R. L., Reindl, D. T., Anderson, J. R., … Graef, P. T. (2013). Ventilation for acceptable indoor air quality. ASHRAE Standard, 8400(STANDARD 62.1), 1–70.
- Hu, J., Li, N., Lv, Y., Liu, J., Xie, J., & Zhang, H. (2017). Investigation on indoor air pollution and childhood allergies in households in six Chinese cities by subjective survey and field measurements. International Journal of Environmental Research and Public Health, 14(9), 1–21. https://doi.org/10.3390/ijerph14090979
- Kabirikopaei, A., Lau, J., Nord, J., & Bovaird, J. (2021). Identifying the K-12 classrooms’ indoor air quality factors that affect student academic performance. Science of the Total Environment, 786, 147498. https://doi.org/10.1016/j.scitotenv.2021.147498
- Lam, K. P., Höynck, M., Dong, B., Andrews, B., Chiou, Y. S., Zhang, R., Benitez, D., & Choi, J. (2009). Occupancy detection through an extensive environmental sensor network in an open-plan office building. IBPSA 2009 – International Building Performance Simulation Association 2009, 1452–1459.
- Lee, J. H., Lee, H. S., Park, M. R., Lee, S. W., Kim, E. H., Cho, J. B., Kim, J., Han, Y., Jung, K., Cheong, H. K., Lee, S. Il, & Ahn, K. (2014). Relationship between indoor air pollutant levels and residential environment in children with atopic dermatitis. Allergy, Asthma and Immunology Research, 6(6), 517–524. https://doi.org/10.4168/aair.2014.6.6.517
- Liao, C., & Barooah, P. (2010). An integrated approach to occupancy modeling and estimation in commercial buildings. Proceedings of the 2010 American Control Conference, ACC 2010, 3130–3135. https://doi.org/10.1109/acc.2010.5531035
- López, L. R., Dessì, P., Cabrera-Codony, A., Rocha-Melogno, L., Kraakman, B., Naddeo, V., Balaguer, M. D., & Puig, S. (2023). CO2 in indoor environments: From environmental and health risk to potential renewable carbon source. Science of The Total Environment, 856, 159088. https://doi.org/10.1016/j.scitotenv.2022.159088
- Moses, L., Morrissey, K., Sharpe, R. A., & Taylor, T. (2019). Exposure to indoor mouldy odour increases the risk of asthma in older adults living in social housing. International Journal of Environmental Research and Public Health, 16(14), 1–14. https://doi.org/10.3390/ijerph16142600
- Pirapuraj, P., Minnoli, N. V., Saranrai, M., & Thevaruban, K. (2021). Automated Ventilation System for Maintaining indoor CO2 Concentration to Reduce Allergic and Respiratory Diseases: For Rural Area in Batticaloa, Sri Lanka. 2021 Asian Conference on Innovation in Technology, ASIANCON 2021, October. https://doi.org/10.1109/ASIANCON51346.2021.9544870
- h. Kurtzman, J. (2010). Ventilation for mushroom cultiVation: the importance of the needs of mushrooms and of the gas laws. Micología Aplicada International, 22, 63–78.
- Seppänen, O. A., & Fisk, W. J. (2004). Summary of human responses to ventilation. Indoor Air, Supplement, 14(SUPPL. 7), 102–118. https://doi.org/10.1111/j.1600-0668.2004.00279.x
- Sharma, S., & Rawat, D. (2018). Partial Pressure Of Oxygen (PO2). In StatPearls. StatPearls Publishing. http://www.ncbi.nlm.nih.gov/pubmed/29630271
- Shriram, S., Ramamurthy, K., & Ramakrishnan, S. (2019). Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric test. Building and Environment, 149(September 2018), 58–67. https://doi.org/10.1016/j.buildenv.2018.12.015
- Stafford, T. M. (2015). Indoor air quality and academic performance. Journal of Environmental Economics and Management, 70, 34–50. https://doi.org/10.1016/j.jeem.2014.11.002
- Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., Samet, J. M., Spengler, J. D., Taylor, S. T., & Weschler, C. J. (2011). Ventilation rates and health: Multidisciplinary review of the scientific literature. Indoor Air, 21(3), 191–204. https://doi.org/10.1111/j.1600-0668.2010.00703.x
- Swiatczak, P., Cydzik-Kwiatkowska, A., & Rusanowska, P. (2017). Microbiota of anaerobic digesters in a full-scale wastewater treatment plant. Archives of Environmental Protection, 43(3), 53–60. https://doi.org/10.1515/aep-2017-0033
- Taylor, S. T., Persily, A. K., Burge, H., Daynard, R., Fanger, P. O., Fickes, E. A., Fisher, F. J., Gallo, F. M., Halliwell, J. L., Hart, K. Q., Hodgson, M. J., Huza, M. A., Mauney, J. M., Morris, R. A., Naughton, D. M., Offerman, F. J., Rasmussen, R. D., Reese, J. A., Schoen, L. J., … Hittle, D. C. (2016). Ventilation for Acceptable Indoor Air Quality. 2016.
- Tian, H., Zhu, L., Ni, J., Wei, T., Wang, P., Xiao, H., & Chen, X. (2023). Indoor CO2 removal: decentralized carbon capture by air conditioning. Materials Today Sustainability, 22, 100369. https://doi.org/10.1016/J.MTSUST.2023.100369
- Tsai, D. H., Lin, J. S., & Chan, C. C. (2012). Office workers’ sick building syndrome and indoor carbon dioxide concentrations. Journal of Occupational and Environmental Hygiene, 9(5), 345–351. https://doi.org/10.1080/15459624.2012.675291
- Verma, S. K., Anand, Y., & Anand, S. (2018). CFD based Modelling of a Ceiling Fan in a Room. International Journal of Scientific and Technical Advancements, 4(2), 219–224.
- Yu, B. F., Hu, Z. B., Liu, M., Yang, H. L., Kong, Q. X., & Liu, Y. H. (2009). 95444444. International Journal of Refrigeration, 32(1), 3–20. https://doi.org/10.1016/j.ijrefrig.2008.05.004
- Zhang, X., Wargocki, P., Lian, Z., & Thyregod, C. (2017). Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self-assessed acute health symptoms, and cognitive performance. Indoor Air, 27(1), 47–64. https://doi.org/10.1111/ina.12284